TROUBꢀESHOOTINꢁ
TROUBꢀESHOOTINꢁ
DISpꢀAY IS BꢀANK
HEATINꢁ SYSTEM DOES NOT RESpOND
“HEATINꢁ” AppEARS ON SCREEN)
COOꢀINꢁ SYSTEM DOES NOT RESpOND
(“COOꢀINꢁ” AppEARS ON SCREEN)
HEAT/COOꢀ BOTH ON AT SAME TIME
(
•
•
Check circuit breaker and reset if necessary.
• Check SW1 (Equipment Type), to make sure it is set
to match the installed heating/cooling equipment
(see page 11)
•
•
•
Check for 24 VAC at the equipment on the secondary
side of the transformer between power and
common. If voltage is not present, check the heating
equipment to find the cause of the problem.
• Check for 24 VAC at the equipment on the secondary
side of the transformer between power and
common. If voltage is not present, check the cooling
equipment to find the cause of the problem.
Make sure power switch at heating & cooling
system is on
•
Check to make sure heating and cooling wires are
not shorted together
•
•
Make sure furnace door is closed securely.
If thermostat is battery powered, make sure fresh AA
alkaline batteries are correctly installed
• Check for 24 VAC between the cooling terminal (Y)
and the transformer common. If 24 VAC is present,
the thermostat is functional. Check the cooling
system to find the cause of the problem
Check for 24 VAC between the heat terminal (W)
and the transformer common. If 24 VAC is present,
the thermostat is functional. Check the heating
equipment to find the cause of the problem.
HEATINꢁ EQUIpMENT IS RUNNINꢁ IN
COOꢀ MODE
TEMpERATURE SETTINꢁS DO NOT CHANꢁE
•
Check SW1 (Equipment Type), to make sure it is set
to match the installed heating/cooling equipment
(see page 11)
Check for loose or broken wires between the
thermostat and the heating equipment.
• Check for loose or broken wires between the
thermostat and the cooling equipment.
Make sure heating and cooling temperatures are set to
acceptable ranges:
•
•
Heat: 45° to 90°F (7° to 32°C).
Cool: 50° to 99°F (10° to 37°C).
fAN DOES NOT TURN ON IN A CAꢀꢀ fOR HEAT
“
HEATINꢁ” IS NOT DISpꢀAYED
•
•
Check System Setting #02 (Fan Control), to make
sure the fan control is properly set to match the type
of system (see page 11)
•
•
Change the System Mode to Heat, and set
the temperature level above the current room
temperature
HEAT pUMp ISSUES COOꢀ AIR IN HEAT MODE,
OR ꢂARM AIR IN COOꢀ MODE
“
COOꢀINꢁ” IS NOT DISpꢀAYED
Change the System Mode to Cool, and set
the temperature level below the current room
temperature
Check System Setting #12 (Reversing Valve), to make
sure it is properly configured for your system (see
page 12)