Aube TH110A DP P Thermostat User Manual

Home

href="
BEFORE  
AFTER  
B
MODEL TH110A-DP-P  
2
40 VAC  
B
B
SUMMARY  
u
6
0 HZ  
OPTIONS SELECTION  
B
At the back of the thermostat, there are 3 selection switches to set at  
your preferences.  
Temperature in °C or °F, time in 12 or 24 hours and Early Start function.  
u
u
TO SET TIME AND DAY  
Press on DAY, HOUR and MIN buttons to adjust time and day.  
NOTE: All cables and connections must conform to the local electrical code.  
TO RECORD THE  
Select chosen setpoint temperature by using  
button (app. 3 seconds) until icon appears on display.  
(COMFORT) SETPOINT TEMPERATURE  
WARNING: Special CO/ALR solderless connectors must be used when  
connecting with aluminum conductors.  
or button. Press on  
u
u
TO RECORD THE  
Select chosen setpoint temperature by using  
Press on button (app. 3 seconds) until icon appears on display .  
(ECONOMY) SETPOINT TEMPERATURE  
Power-up  
or button.  
Set the On/Off switch to On.  
When power is applied for the first time, the  
display must show the time 00:00, the room  
TO RECORD THE  
To program the Vacation temperature, select the desired degree using the  
buttons and press on the and buttons simultaneously  
icon is displayed (app. 3 seconds).  
(VACATION) SETPOINT TEMPERATURE  
temperature and the Manual mode icon (  
).  
Other information might show up on the display if  
installation is defective or does not comply with the  
instructions.  
until the  
u
OPERATING MODES  
To select an operating mode, use MODE button.  
NOTE: The On/Off switch set to Off will place the  
thermostat in sleep mode. Ideal for sum-  
mertime.  
AUTO:  
Runs the program.  
and can override temporarily your programming up to the  
next program.  
or  
shows temperature setting  
MAN:  
Maintains the selected temperature.  
the temperature setting.  
or  
changes  
OPERATING MODES  
The TH110A-DP-P has two (2) operating modes.  
MANUAL (  
)
This mode allows you to maintain a constant temperature in the room.  
1- To activate this mode, press on Mode button to display the  
icon.  
2
- Set the desired temperature using the  
buttons or select the  
simultaneously.)  
pre-programmed  
To select the  
or  
or  
settings.  
and  
(
setting, press on  
AUTOMATIC (  
This mode executes your own programming.  
To activate this mode, press on Mode button to display the  
The or icon indicates which temperature setting is used. Also, the icon  
)
icon.  
of the program number will be shown.  
Memory back-up  
In the event of a power failure, an internal circuit will maintain the programming  
and the time. But only the time could have to be set if power failure is more than  
2
hours.  
Early Start function  
The thermostat is providing a built-in function enabling it to calculate the  
optimum time to start the heating system to achieve the desired temperature  
setting at the programmed time. This function could start the heating system as  
early as 6 hours prior to the programmed time. To enable this function, set the  
switch E.S. to “ON” at the back of the thermostat.  
PROGRAMMING  
Programming the time and day  
INSTALLATION  
1- Set the time using the Hour and Min buttons.  
NOTE: The "Problems and Solutions" section at the end of this user's guide will  
2- Set the day using the Day button.  
help you to correct your problems during the installation.  
Programming the Comfort, Economy and Vacation settings  
This thermostat has been designed to operate with any installation  
which has a RESISTIVE load not exceeding 4000 W (16.67 A) @ 240 VAC  
such as electric baseboards, radiant ceilings and floors, electric con  
vectors, etc. It is not compatible with a low voltage controller used by  
a central heating system.  
The Comfort settings respectively represent  
the temperatures that you wish to have during the day  
are away at work  
, Economy  
and Vacation  
, at night or while you  
.
, or while you are away for an extended period  
Electricians or experienced technicians should install the thermostat.  
This thermostat is designed to be used with a self-protected heating  
system equipped with thermal cut off and circuit breaker.  
PARTS INCLUDED  
-
-
-
One (1) TH110A-DP-P (240 VAC) thermostat  
Two (2) 6-32 screws  
Four (4) solderless connectors (for copper wire)  
TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER  
PANEL TO AVOID ELECTRICAL SHOCK. Keep air vents of the thermostat clean  
and free from obstructions.  
920-110-003-00-1-A 1/2  
href="
To program your settings  
To modify the Saturday and Sunday schedules:  
a) To program the Comfort temperature, select the desired degree using the  
6- Press on Day button until SA or SU is displayed.  
buttons and press the  
app. 3 seconds).  
b) To program the Economy temperature, select the desired degree using the  
buttons and press the button until the icon is displayed  
app. 3 seconds).  
button until the  
icon is displayed  
7
-
Press on PGM button to select Prog. 1 (  
buttons to enter 7:30 AM.  
) and Hour and Min  
(
8- Press on PGM button to select Prog. 2 (  
erase it.  
) and then Clear button to  
) and then Clear button to  
) and then Hour and Min  
(
9-  
Press on PGM button to select Prog. 3 (  
erase it.  
c) To program the Vacation temperature, select the desired degree using the  
buttons and press on the and buttons simultaneously  
icon is displayed (app. 3 seconds).  
until the  
10- Press on PGM button to select Prog. 4 (  
buttons to enter 11:00 PM.  
d) Press the Mode button to exit this function and return to the normal  
operating mode.  
11- Press on Mode button to exit this function.  
Schedule programming  
Temporary or permanent temperature bypass  
This operation allows you to temporarily modify the room temperature while you  
are in the Automatic mode. Simply press on or button to select the desired  
temperature, or the or button to select the Comfort or Econo settings you  
have programmed.This temperature will be maintained until the beginning of the  
next programmed schedule.  
The TH110A-DP-P allows 4 setting changes for each day of the week. There are  
no pre-set programs.The programs are tailored to perfectly adapt to your life  
style. The principle is very simple. For each day, enter the time at which you wake  
up (P1), the time you leave for work (P2), the time you arrive back home (P3) and  
the time you go to bed (P4).  
You can also switch to the Vacation setting for a prolonged absence by pressing  
Program  
Mode  
Time  
on  
and  
at the same time.The display will show  
icon. In that case,  
1
2
3
Wake-up time  
Leaving time  
the derogation is permanent. To return to the normal operating mode, press on  
Mode button.  
If you wish to immediately return to the programmed settings, press on Mode  
button twice.  
Return time  
Bed time  
4
CHARACTERISTICS  
For savings to be obtained, you must lower the temperature for a period of 2 to 3  
times the delay required to bring the temperature back to your comfort level.  
Model:  
TH110A-DP-P (240 VAC)  
240 VAC, 50/60 Hz  
16.67 A maximum (resistive only)  
4000 watts (NI) @ 240 VAC  
CSA / UL  
Example : If your system takes one hour to go from your saving temperature level  
to your comfort temperature Ievel, it is useless to lower the temperature for a  
period less than 2 to 3 hours.  
• Supply:  
Load:  
Power:  
Approvals:  
Display range:  
Setting range:  
a) To program your schedule  
0 to 60 °C (32 to 140 °F)  
5 to 30 °C (40 to 85 °F)  
20 °C (68 °F)  
1- Press on PGM button to access the programming mode.  
2- Press on Day button to select the day to be programmed. You can select  
all days of the week by pressing on Day button for 3 seconds.  
• Comfort default setting:  
• Econo default setting:  
• Vacation default setting:  
• Storage:  
3
4
5
- Press on PGM button to select program 1, 2, 3 or 4.  
18 °C (64 °F)  
- Press on Hour and Min buttons to program the time.  
10 °C (50 °F)  
- When you have completed your programming, press on Mode button  
to exit this function.  
-20 to 50 °C (-4 to 120 °F)  
b) To erase a program :  
Select the program using PGM and Day buttons, and press on Clear  
button. The time field displays --:-- when the program is inactive.  
WARRANTY  
AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY  
c) Example 1 : Comfort period from 7:00 AM to 10:30 PM  
Economy period from 10:30 PM to 7:00 AM  
This product is warranted against material defects and workmanship in normal  
use for a period of one year, from the date of the original purchase from  
authorized dealers. During this period, AUBE technologies inc. will repair or  
replace the product with a new or of equivalent quality at AUBE'S option, without  
charge, any product proven defective in normal use.  
Identical schedule for all days of the week.  
1
2
3
4
- Press on PGM button to access the programming mode.  
- Press on Day button 3 seconds to select every day of the week.  
Warranty does not cover transportation costs. Nor does it cover a product  
subjected to misuse or accidental damage. This warranty does not cover the cost  
of installation, removal or reinstallation.  
- Press on Hour button to enter 7:00 AM, Prog. 1 (  
).  
- Press on PGM button again to select Prog. 2 (  
Hour and Min buttons to enter 10:30 PM.  
), and press on  
This limited warranty is in lieu of all other warranties, obligations or liabilities  
expressed or implied by the company. In no event shall AUBE technologies inc.  
be liable for consequential or incidental damages resulting from installation of this  
product. Some states or provinces do not allow limitations on how long an implied  
warranty lasts, or the exclusion or limitation of incidental or consequential  
damages, so the above exclusions or limitations may not apply to you. This  
warranty gives you specific legal rights and you may also have other rights which  
vary from state to state.  
5- Press on Mode button to exit this function.  
d) Example 2 : Comfort period: Monday to Friday from 6:15 AM to  
:15 AM and from 5:00 PM to 10:00 PM.  
Saturday & Sunday from 7:30 AM to 11:00 PM.  
8
The defective product and the original sale receipt must be returned to the  
original dealer or shipped pre-paid, insured and addressed to:  
Schedule/Day MON.  
TUES.  
WED.  
THU.  
FRI.  
SAT.  
SUN.  
PROG. 1  
PROG. 2  
PROG. 3  
PROG. 4  
6:15 AM 6:15 AM 6:15 AM 6:15 AM 6:15 AM 7:30 AM 7:30 AM  
Aube technologies inc., 705 Montrichard, Iberville (Quebec),  
Canada, J2X 5K8  
8
:15 AM 8:15 AM 8:15 AM 8:15 AM 8:15 AM  
---  
---  
---  
---  
5
PM  
5 PM  
5 PM  
5 PM  
5 PM  
www.aubetech.com  
10 PM  
10 PM  
10 PM  
10 PM  
10 PM  
11 PM  
11 PM  
If you have any questions concerning the installation or programming of this  
product, please call our technical assistance at (450) 358-4600 for the Montreal  
NOTE:  
It is faster to program the same schedule for every day and then  
modify the exception days.  
area or 1-800-831-AUBE for outside area, Monday to Friday between  
8:30 AM and 5:00 PM Eastern time.  
1
2
3
4
- Press on PGM button to access the programming mode.  
- Press on Day button 3 seconds to select every day of the week.  
- Press on Hour and Min buttons to enter 6:15 AM, Prog. 1 (  
).  
- Press on PGM button to select Prog. 2 (  
enter 8:15 AM.  
) and Hour and Min buttons to  
5- Repeat step 4 to enter Prog. 3 (5:00 PM) and Prog. 4 (10:00 PM).  
NOTE: When making modifications, make sure you are in the right  
program.  
05/07/02  
920-110-003-00-1-A 2/2  
href="
PROBLEMS AND SOLUTIONS  
PROBLEMS  
CAUSES  
SOL  
No display  
• Circuit breaker is open  
• Check 240 VAC presence  
at the thermostat  
Power failure  
The thermostat switch is  
in Off position  
• Put the switch  
in On position  
The thermostat is loosing  
the time but not the programming  
• Power failure more than  
2 hours  
Room temperature shown is wrong  
• A draft is nearby the thermostat  
• Eliminate the draft  
Programs do not change as you want  
• Incorrect programming hours  
• Check actual time  
in AM & PM as well  
as program times  
Wrong programming mode selected  
(
AM is not displayed)  
Make sure operating mode  
is set to AUTO  
PROBLÈMES ET SOLUTIONS  
PROBLÈMES  
CAUSES  
SOLUTIONS  
Pas d'affichage  
•Disjoncteur ouvert  
• Vérifiez la présence  
du 240 Vca au thermostat  
• Placez l’interrupteur en  
position On  
Panne de courant  
L’interrupteur du thermostat  
est en position Off  
Le thermostat perd l'heure  
mais pas la programmation  
•Panne de courant de longue  
durée (plus de 2 heures)  
Affichage de la température ambiante  
incorrect  
• Courant d'air à proximité  
• Éliminez les courants d'air  
• Vérifiez l'installation  
Système de chauffage toujours  
en marche  
• Mauvaise installation  
UTIONS  
Le thermostat affiche du chauffage mais le  
sytème de chauffage  
ne chauffe pas  
• Mauvaise installation  
• Vérifiez l'installation  
• Vérifiez la présence du  
240 Vca au système de chauffage  
Les programmes ne changent pas comme  
vous le souhaitez  
• Heures de programmation  
incorrectes  
Mauvais mode d'opération  
sélectionné  
• Vérifiez les heures actuelles  
de programmation  
(attention au format AM  
et PM, AM n'est pas affiché)  
Assurez-vous que vous avez  
choisi le mode d'opération  
AUTO  
PROBLEMAS Y SOLUCIONES  
PROBLEMAS  
CAUSAS  
SOLUCIONES  
La pantalla no marca  
•Disyuntor abierto  
• Verifique la presencia de 240 Vca  
del termostato  
• Colóquo en On  
Corte de corriente eléctrica  
El interruptor se encuentra en Off  
El termostato pierde la hora pero  
no la programación  
•Pérdida de corriente de larga duración  
(más de 2 horas)  
Marca la temperatura ambiente incorrecta  
• Corriente de aire a proximidad  
• Elimine la corriente de aire  
• Verifique la instalación  
Sistema de calefacción siempre en marcha  
• Mala instalación  
El termostato marca la calefacción pero el  
sistema de calefacción no calienta  
• Mala instalación  
• Verifique la instalación  
• Verifique la presencia del  
2
40 Vca en el sistema de calefacción  
Los programas no cambian como usted  
desea  
• Horas de programación incorrectas  
• Selección de un modo de operación erróneo  
• Verifique las horas de programación  
actuales (cuidado con el ciclo  
AM y PM, AM no aparece  
en pantalla)  
Asegúrese de haber elegido  
el modo de operación AUTO  
11/06/01  
25/06/02 920-110-003-00-1-A  
3/3  

White Rodgers 37 5148B Thermostat User Manual

Lux Products TX9100E Thermostat User Manual

Honeywell Q682C Thermostat User Manual

White Rodgers F145 1082 Thermostat User Manual

Carrier 33CSIRRCVR 01 Thermostat User Manual

Honeywell 7500 Thermostat User Manual

Honeywell AQ1000TN2 Thermostat User Manual

White Rodgers 37E73A 918 Thermostat User Manual

Bryant A07049 Thermostat User Manual

Honeywell Q674G Thermostat User Manual