Introduction
Control Module Installation
Operation
TH1 1 3-R Regulator
User Guide
Thank you for choosing Aube’s TH113-R Regulator.
Align the bracket tabs on the regulator with the holes
located on the power base.
The TH113-R regulator operates on perpetual 15-minute
heating cycles.
The TH113-R is specially designed to control a floor
heating installation, a baseboard or a convector.
Control Module
For example, if the dial is set
halfway, the system will heat
for 50% of the cycle; it will be
ON for 7.5 minutes and OFF
for 7.5 minutes.
The TH113-R regulator operates like a dimmer switch to
allow you to easily adjust the amount of power sent to
your heating system.
GFCI Test
and Warning
Light
It features an integrated GFCI, and includes a test button
and warning light for added security.
Below is a detailed table of the
cycle duration based on the
dial’s position:
This regulator is also equipped with an ON/STANDBY
switch making it possible to put it in sleep mode when its
use is not required (e.g. summer).
On/StandBy
Switch
IMPORTANT!
Position and
equivalent %
I
2
20%
4
40%
6
60%
8
10
0%
80% 100%
The GFCI and Remote Input options are not available
with a low voltage power base. Skip sections 3 and 4.
ON
0 min 3 min 6 min 9 min 12 min 15 min
15 min 12 min 9 min 6 min 3 min 0 min
Power Base
OFF
Power
Selection
Dial
This regulator must be installed on a PB112 power
base.
The screw cannot be removed completely.
Keep the regulator’s air vents clean and free from
obstructions.
NOTE: Depending on the power base used, the heating
cycles can be 15 seconds or 15 minutes.
Technical Specifications
GFCI Test (GA/GB line power base only)
Remote Input (line voltage only)
If you have any questions concerning the TH113-R
Regulator, call our technical support team at:
Model: TH113-R
The GFCI monitors the electrical flow for any loss of
current; if there is any loss, the thermostat will cut off
power to the heating system.
When a remote control interface (Aube CT241 or any
other remote control system) is connected to the power
base’s remote input and a signal is received, the TH113-R
module automatically lowers the percentage by 35%
based on the dial’s current position.
Power setting range: 0 to 100%
Storage: -20°C to 50°C (-4°F to 120°F)
Phone:
Montreal area:
Canada / U.S.:
(450) 358-4600
We recommend you test the GFCI immediately after
installing the control module, and once a month thereafter
to ensure it is operating properly.
Warranty
1-800-831-AUBE (2823)
(450) 358-4650
Fax:
The LED lights up to indicate the signal’s presence
AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED
WARRANTY
(
except for GA and GB models).
Email:
To test:
This product is guaranteed against workmanship defects for a one
year period following the initial date of purchase. During this period,
AUBE Technologies Inc. will repair or replace, at our option and
without charge, any defective product which has been used under
normal conditions.
n
Press the TEST button:
•
Successful: TEST warning
light is ON and power to
The TEST button can be used to bypass the signal for a
2-hour period.
Monday to Friday from 8:30 AM to 5:00 PM EST.
heating system is cut off.
The warranty does not cover delivery costs and does not apply to
products poorly installed or randomly damaged following installation.
This warranty cancels and replaces any other manufacturer's
express or implied warranty as well as any other company
commitment.
The LED goes off to indicate the bypass.
•
Unsuccessful: TEST warning
light is OFF.
NOTE: When combined with a GA or GB power base, the
TEST button is used only for GFCI testing. The
percentage is decreased, but the bypass function and
indicator are not available.
For more information on our products, visit us at:
Cut power to heating system from the main power
panel and call customer service.
www.aubetech.com
AUBE Technologies Inc. cannot be held liable for related or random
damages following the installation of this product. The defective
product as well as the purchase invoice must be returned to the
place of purchase or mailed, prepaid and insured, to the following
address:
o
When successful, reset thermostat (STANDBY/ON)
to power heating system.
NOTE: If the test warning light comes ON during normal
operation, cut power to heating system from the main
power panel and have an electrician verify the installation.
Aube Technologies Inc.
705 Montrichard
Saint-Jean-sur-Richelieu, Quebec, Canada J2X 5K8
0
5/11/03 400-113-004-A