Aube TH114 Thermostat User Manual

Home

href="
TH1 1 4  
User!s Guide  
Non-programmable Thermostat  
1
.
Description  
3. Installation  
Aube’s TH114 Series non-programmable thermostats can be used  
to control ambient or floor temperature. The following models are  
available:  
n Refer to the installation instructions of the  
power base.  
o Insert the tabs at the top of the control  
module in the slots at the top of the  
power base.  
A model:  
F model:  
controls and displays the ambient temperature  
p Secure the control module using the cap-  
tive screw underneath the base.  
controls and displays the floor temperature  
uses an external temperature sensor  
Note: Do not obstruct the thermostat's vents.  
AF model:  
controls and displays the ambient temperature  
maintains the floor temperature within desired  
limits  
4
.
Power-up  
uses an external temperature sensor  
As soon as the thermostat is powered, it undergoes a  
series of tests before displaying the actual tempera-  
ture.  
GFCI fault light *  
Actual or setpoint  
temperature  
5. Error Messages  
Arrow appears  
when the setpoint  
is displayed  
The measured temperature is below 0°C (32°F). Heat-  
ing is turned On.  
GFCI fault indicator *  
Power output  
1 to 24%  
25 to 49%  
50 to 74%  
75 to 99%  
100%  
The measured temperature is above 50°C (122°F) (A  
or AF model) or 60°C (140°F) (F model).  
Temperature  
adjustment button  
GFCI test button * /  
Backlight button *  
The floor sensor is defective or not properly connected  
(F model only), or the thermostat is defective.  
On/Standby button  
6
.
GFCI Test  
*
available on certain models only  
Note: This procedure must be performed if the thermostat is  
mounted on a GFCI-equipped power base.  
Each thermostat consists of a control module which must be  
mounted on a PB112 Series power base. For the selection and  
installation of the power base, refer to its installation instructions.  
Test the GFCI immediately after installing  
the control module, and once a month there-  
after.  
2
.
DIP Switch Configuration  
n Raise the temperature  
until the heat-  
appears.  
The DIP switches are located at  
the back of the control module.  
ing power indicator  
o Press the Test button.  
2
.1 Temperature Display (S1 )  
p If the test is successful, you will hear a  
click caused by the GFCI relay tripping.  
The heating power indicator will disap-  
pear, GFI will appear and the Fault light  
will illuminate. Reset the thermostat by  
switching it to Standby and back to On.  
To switch between °C and °F.  
2
.2 Model (S2)  
Note: Available on certain models only  
F: To select the F model  
q If the test has failed, cut power to the heating system from the  
main electrical panel and call customer service.  
AF: To select the A or AF model  
Note: If the Fault light is On during normal operation, cut power to  
heating system at the main electrical panel and have an electrician  
verify the installation.  
TH114  
400-114-000-B  
21/2/05  
1/2  
href="
8
.
Technical Specifications  
7
.
Operation  
Power supply: Refer to the power base installation instructions.  
Ambient setpoint range (A/AF models): 5°C to 30°C (40°F - 86°F)  
Floor limit range (AF model): 5°C to 40°C (40°F - 104°F)  
Floor setpoint range (F model): 5°C to 40°C (40°F - 104°F)  
Setpoint resolution: ± 0.5°C (1.0°F)  
7
.1 Backlight  
When either of the  
seconds. The setpoint appears for 5 seconds, then the actual tem-  
perature is displayed.  
buttons is pressed, the display is lit for 10  
When the backlight button is pressed, the display is lit for 5 sec-  
onds. NOTE: If the thermostat is mounted on a GFCI-equipped  
power base, this button is used for the GFCI test.  
Display resolution: ± 0.5°C (1.0°F)  
Duty cycle: Refer to the power base installation instructions.  
Storage: -20°C to 50°C (-4°F - 120°F)  
7
.2 Displaying and Setting the Temperature  
9
.
Warranty  
The thermostat normally displays the actual temperature. To view  
the setpoint, press once on one of the buttons. The setpoint is  
displayed for 5 seconds. During the setpoint display, press one of  
the buttons to change it. To scroll the setpoint faster, press  
and hold the button.  
AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY  
This product is guaranteed against workmanship defects for a one  
year period following the initial date of purchase. During this period,  
AUBE Technologies Inc. will repair or replace, at our option and  
without charge, any defective product which has been used under  
normal conditions.  
7
.3 Setting the Floor Temperature Limits (AF model only)  
The warranty does not cover delivery costs and does not apply to  
products poorly installed or randomly damaged following installa-  
tion. This warranty cancels and replaces any other manufacturer's  
express or implied warranty as well as any other company commit-  
ment.  
The thermostat generally turns heating On or Off to con-  
trol the ambient temperature. However, if the floor tem-  
perature drops below the set minimum floor temperature  
limit or rises above the maximum limit, the thermostat  
will turn heating On or Off respectively, regardless of the  
ambient temperature, to maintain the floor temperature  
within the desired limits.  
AUBE Technologies Inc. cannot be held liable for related or random  
damages following the installation of this product. The defective  
product as well as the purchase invoice must be returned to the  
place of purchase or mailed, prepaid and insured, to the following  
address.  
The minimum and maximum floor temperature limits are  
factory-set at 10°C (50°F) and 28°C (82°F) respectively. To modify  
the limits, proceed as follows:  
n Switch the thermostat to Standby.  
1 0. Service  
o While pressing any button, switch the thermostat back to On to  
7
05 Montrichard  
access the floor temperature limit settings.  
Saint-Jean-sur-Richelieu, Quebec  
J2X 5K8  
Canada  
p Press the Test button briefly to switch between minimum and  
maximum floor temperature settings.  
T: (450) 358-4600  
q Press the  
buttons to set the desired limit.  
1
-800-831-AUBE (2823)  
r Press the Test button for 3 seconds to save your modifications.  
After the data are saved, the thermostat displays the actual  
ambient temperature or “– –”.  
F: (450) 358-4650  
Note: Your modifications are also saved if no button is pressed for  
For more information on our products, visit us at:  
6
0 seconds.  
www.aubetech.com  
s Switch the thermostat to Standby and back to On to reset the  
GFCI and return to the normal display.  
:
TH114  
400-114-000-B  
21/2/05  
2/2  
href="
PB112-024T-15S  
Installation Instructions  
24 V Low-Voltage Power Base  
1
.
s Install the control module onto the base.  
t Apply power to the heating system.  
Applications  
n
The PB112-024T-15S power base can be used on any TH11x series  
thermostat (with the exception of the TH110 model). This low-voltage  
power base operates on 15-second cycles and can be connected to  
a line-voltage load using a solid-state relay. The PB112-024T-15S is  
compatible with most solid-state relays; however, the following Aube  
relays are optimized for use with this power base:  
u Verify the installation by checking that the heating system can be  
turned on or off using the thermostat.  
4.1  
Single SSR with Built-in Transformer  
RT850 solid-state relay (SSR)  
RT850T solid-state relay (SSR) with built-in 24-V transformer  
WARNING  
Electrical  
Panel  
Blue  
Red  
This power base MUST be used ONLY with solid-state relays. The  
use of electromechanical relays will result in reduced life expect-  
ancy and in the possibility of overheating of these devices.  
Black  
Heater  
2
.
4
.2  
Multiple SSRs with External Transformer  
Supplied Parts  
o
n One (1) power base  
o Two (2) plastic anchors  
p Two (2) mounting screws  
Electrical  
Panel  
3
.
Black  
Red  
External 24 V  
Transformer  
Installation Guidelines  
For a new installation, choose a location about 1.5 m (5 ft.)  
above the floor.  
The thermostat must be installed on an inside wall facing the  
heating system (except for floor heating systems).  
Avoid locations where there are air drafts (top of staircase, air  
outlet), dead air spots (behind a door), direct sunlight or  
concealed chimney or stove pipes (except for floor heating  
systems).  
p
Heater  
Heater  
Black  
Red  
5
.
Technical Specifications  
Maximum load: 0.5 A / 24 VAC  
r
4
.
Installation Procedure  
The installation must be carried out by an electrician and com-  
ply with local electrical codes.  
Heating cycle length: 15 seconds  
q
Operating temperature: 32°F to 122°F (0°C to 50°C)  
Storage: -4°F to 122°F (-20°C to 50°C)  
Size (H • W • D): 124 x 70 x 23 mm (4.89 x 2.76 x 0.91 in)  
Wire gauge: 14 to 22 AWG  
n Turn off power to the heating system at the main electrical panel  
to avoid electrical shock.  
o Wire the base according to your application. See typical wiring  
diagrams in sections 4.1 and 4.2.  
p For a floor heating system installation, con-  
nect the floor sensor between the S and R ter-  
minals.  
q Secure the base to the wall using the provided screws and wall  
anchors.  
r Configure the switches located on the control module (if any).  
Refer to the user guide.  
PB112-024T-15S  
400-112-024-A  
18/1/06  
1/1  

White Rodgers 1F94 71 Thermostat User Manual

Honeywell AC 140 7 Thermostat User Manual

White Rodgers 1F30(W) Thermostat User Manual

Lux Products TX9100E Thermostat User Manual

Honeywell L91F Thermostat User Manual

Honeywell TH8000 Thermostat User Manual

Aprilaire 8061 Thermostat User Manual

Aube TH136 Thermostat User Manual

Honeywell RTH6500WF Thermostat User Manual

Honeywell 3355 Thermostat User Manual