Aube TH136 Thermostat User Manual

Home

href="
2
.
TH136 Programmable  
Thermostat  
Remote Input Wiring  
The TH136 is equipped with a remote input which allows connection of a  
telephone controller (optional CT240) or a home automation system.  
When a signal is received through this input, the TH136 will automatically  
o
Owner’s Guide  
Your new electronic thermostat is equipped with a microprocessor  
with proportional integral adaptive (PIA) temperature control  
technology for total comfort.  
switch from normal operating mode to Frost Protection  
versa.  
mode, or vice  
NOTE: For details on operating the telephone controller, see Operating  
Modes.  
2.1  
Connection to the CT240  
Connect CT240 terminals A and C to  
TH136 terminals X and C respectively.  
You must respect the polarity.  
2.2  
Connection to a home  
automation system  
Connect the TH136 to the home  
automation system as displayed in the  
wiring diagram.  
n Clock/Day settings  
q Heating is On  
r Return/Exit  
u Auto mode  
o Setpoint is displayed  
v Current program  
w Adjustment buttons  
when arrow appears  
s Power (On/Off)  
t Manual mode  
3.  
p Program settings  
Installing the Batteries  
p
1
.
When you first install the batteries, the unit runs a  
sequence of tests which lasts approximately 5 seconds.  
After the tests, the screen should display the current  
temperature.  
Installation & Wiring  
Guidelines  
n
1
.1  
Turn off power to the heating system at the main power panel to  
avoid electrical shock. The installation must be performed by an  
electrician.  
NOTE: We recommend replacing the batteries at least  
once a year.  
The TH136 will display an icon  
indicating that the  
High voltage thermostats must be installed onto an electrical  
box.  
For a new installation, choose a location about 1.5 metres above  
the floor.  
The thermostat must be installed facing the heating system.  
The thermostat must be installed on an inside wall.  
Avoid locations where there are air drafts (top of staircase, air  
outlet), dead air spots (behind a door), direct sunlight or  
concealed chimneys or stove pipes.  
batteries must be replaced. This icon will be displayed  
for 60 days; after this delay, the TH136 will shut down  
the heating unit. Once batteries have been replaced,  
you will have to reprogram the clock & day settings; all  
other programming is stored in a protected memory.  
On/Off Button  
The thermostat is equipped with an On/Off button  
making it possible to put the thermostat in sleep mode  
when its use is not required (e.g. summer). This will not  
affect the clock or programming.  
1.2  
Installation Procedure  
4
.
Clock and Day Settings  
q
n Press ; the hour segment flashes.  
o Press  
p Press ; the minutes segment flashes.  
q Press to set the minutes.  
r Press ; the day flashes.  
to set the hour.  
s Press  
to set the day.  
t Press  
to exit.  
5
.
Operating Modes  
r
5
.1  
Automatic  
Executes the schedule. Press Auto to activate the  
Auto mode.  

5
.2  
Manual  
Maintains a constant temperature. Press  
activate the Manual mode and set the temperature  
to  
n Remove the screw holding the control module to the power  
Automatic  
base.  
using  
.
NOTE: Please note that the screw cannot be completely removed.  
5
.3  
Frost Protection  
o Lift the control module to remove it from the power base.  
Maintains the Frost Protection setpoint during a  
prolonged absence. The Frost Protection setpoint is  
pre-programmed to 10°C. To modify, see Advanced  
Programming. There are 2 ways to activate the  
Frost Protection mode:  
p On the power base, remove the screw holding the wire cover  
and wire the thermostat.  
NOTE: The terminals are designed for wires of cross-section mea-  
suring 0.33 to 2.5 mm2.  
Manual  
n From the thermostat:  
q Once all wiring is complete, secure wire cover.  
Press  
for 1 second to activate the Manual  
r Secure the power base onto the electrical box using the  
mode. Hold  
for 3 seconds. The icon is  
mounting holes.  
displayed. To deactivate the Frost Protection  
mode, activate the Auto or Manual mode.  
s Mount the control module onto the power base and secure using  
the screw.  
Frost Protection  
o
From a telephone (remote location) when the TH136  
is connected to a CT240 telephone controller.  
t Return power to the heating system.  
NOTE: Keep the thermostat's air vents clean and free from obstruc-  
NOTE: For details on how to activate the Frost Protection mode using a  
tions.  
telephone, refer to the CT240 Instruction Manual.  
WARNING: When the Frost Protection mode is activated remotely, it  
must be deactivated remotely.  
TH136  
400-136-001-C  
2008-02-01  
1/2  
href="
5
.4  
Temporary Bypass  
8.2  
Modify the Heating Cycles (CPH)  
When the TH136 is in Auto or Frost Protection mode, you can bypass  
the mode for two (2) hours. The TH136 will maintain the temperature  
bypass for two (2) hours, then return to previous operating mode. Set  
For greater flexibility, you can define the cycle that best suits your  
requirements. The shorter the cycles, the greater your comfort.  
However, your system will be activated more often when using  
shorter cycles.  
the temperature using these buttons  
. The icon corresponding to  
the bypassed mode will flash to indicate the bypass.  
6
.
Cycles/hour  
Length  
30 min.  
20 min.  
15 min.  
12 min.  
10 min.  
Installation  
Commercial unit  
Pre-programmed Schedule  
The TH136 programmable thermostat is pre-programmed with the  
following schedule:  
2
3
4
5
6
s
Commercial unit  
Fuel, gas & electrical furnace  
Direct wiring to circulator  
Direct wiring to circulator  
8
.3  
Modify the Frost Protection Setpoint (HLd)  
Use this menu to modify the Frost Protection setpoint associated with  
the Frost Protection mode. The setting range is between 5°C and  
28°C. Default: 10°C.  
8
.4  
Early Start (ES)  
When Early Start is activated, the TH136 calculates the optimum start  
time to obtain the desired temperature by the programmed set time.  
Time you wake  
up and desired  
temperature  
Time you leave  
and temperature  
during your  
Time you return  
home and  
desired  
temperature  
Time you go to  
bed and  
overnight  
8
.5  
Pump Protection (PP)  
absence  
temperature  
For hot water installations, it is recommended that the pump be  
activated at least 15 seconds every 24 hours to avoid any seizing.  
Programs 1 and 4 are repeated from Monday to Sunday.  
Programs 2 and 3 are repeated from Monday to Friday.  
9.  
Technical Specifications  
7
.
v
Modify the Schedule  
To modify the pre-programmed schedule, follow these steps:  
Power supply: 2 AAA (LR03) alkaline batteries  
Max. resistive load: 5A @ 240 VAC  
Max. inductive load: 2A @ 240 VAC  
Remote input: 12 VDC / ± 10% / 5 mA  
Control device: Electronic  
t
n Press the button associated with the program you wish to  
modify.  
Automatic action: Type 1B  
Storage temperature: -20°C to 50°C  
Operating temperature: 0°C to 50°C, 95% relative humidity without  
condensation  
Temperature setpoint range: 5°C to 28°C  
Temperature setpoint interval: 0.5°C  
Temperature display resolution: 0.1°C  
Temperature display accuracy: ± 0.3°C  
Software: Class A  
o Enter the program start time using the  
p Press the program button again.  
q Enter the desired temperature using the  
buttons.  
buttons.  
r Press  
to exit.  
Protection degree: IP 20  
Environment: normally polluted  
NOTE: After 60 seconds of inactivity, the thermostat will automati-  
cally exit programming mode.  
1
0.  
The TH136 thermostat is equipped with the Early Start function  
Warranty  
;
(deactivated by default). To activate, refer to Advanced  
Programming.  
Aube warrants this product, excluding battery (if applicable), to be free from defects in the  
workmanship or materials, under normal use and service, for a period of three (3) years  
from the date of purchase by the consumer. If at any time during the warranty period the  
product is determined to be defective or malfunctions, Aube shall repair or replace it (at  
Aube's option).  
8
.
Advanced Programming  
You must hold the Auto button for 3 seconds to access the advanced  
programming. Then, press Auto to select a menu.  
u
If the product is defective,  
(
i)  
return it, with a bill of sale or other dated proof of purchase, to the place from which  
you purchased it, or  
ii) contact Aube. Aube will make the determination whether the product should be  
returned, or whether a replacement product can be sent to you.  
(
Menus  
PPd MO  
PPd TU  
PPd WE  
PPd TH  
PPd FR  
PPd SA  
PPd SU  
CPH  
Default  
Options  
0, 2, 4  
This warranty does not cover removal or reinstallation costs. This warranty shall not  
apply if it is shown by Aube that the defect or malfunction was caused by damage which  
occurred while the product was in the possession of a consumer.  
Aube's sole responsibility shall be to repair or replace the product within the terms stated  
above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND,  
INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING,  
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS  
OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some provinces and  
states do not allow the exclusion or limitation of incidental or consequential damages, so  
this limitation may not apply to you.  
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS  
PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WAR-  
RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS  
HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some  
provinces and states do not allow limitations on how long an implied warranty lasts, so  
the above limitation may not apply to you.  
4
4
0, 2, 4  
4
0, 2, 4  
4
0, 2, 4  
4
0, 2, 4  
2
2
0, 2, 4  
0, 2, 4  
5
2, 3, 4, 5, 6  
5°C to 28°C  
OF / ON  
OF / ON  
This warranty gives you specific legal rights, and you may have other rights which vary  
from province or state to another.  
HLd  
10°C  
OF (off)  
OF (off)  
11.  
ES  
 Technical Assistance  
PP  
n Press Auto until the desired menu is displayed.  
o To modify the default programming, use the  
buttons and  
7
05 Montrichard  
10 rue Ampère  
95500 Gonesse  
France  
select from the available options.  
Saint-Jean-sur-Richelieu  
Québec, Canada J2X 5K8  
p Press  
to exit.  
NOTE: Menus are detailed below.  
Tel. : (450) 358-4600  
1-800-831-AUBE  
33 (0) 1 34 07 99 00  
33 (0) 1 34 07 99 19  
8
.1  
Modify the Number of Programs per Day (PPd)  
You can select the number of programs to be executed for each day  
of the week. This means, you can run all 4 programs, only 2 (1st and  
Fax : (450) 358-4650  
4th) or none (0).  
NOTE: When none (0) is selected, the TH136 will maintain the tem-  
For more information on our products, visit us at  
perature setpoint of the last program.  
www.aubetech.com  
TH136  
400-136-001-C  
2008-02-01  
2/2  

White Rodgers 1D56 310 Thermostat User Manual

Aprilaire 8800 UNIVERSAL Thermostat User Manual

Honeywell CT53 Thermostat User Manual

Lux Products TX9100E Thermostat User Manual

Honeywell HE250 Thermostat User Manual

White Rodgers 2816 Thermostat User Manual

Lux Products WTR064 Thermostat User Manual

Trane TAYSTAT 540 Thermostat User Manual

Aube TH113 AF Thermostat User Manual

Honeywell Q7100D Thermostat User Manual