Aube TH148ELE Thermostat User Manual

Home

href="
TH147E & TH148ELE  
Installation and User Guide  
Non-programmable Thermostats  
1
.
2.2 Mounting the thermostat  
Introduction  
n
The TH147E and TH148ELE thermostats can be used to control:  
a forced air system - 2 or 3 wires  
a hot water system with or without pump - 2 wires  
a millivolt system - 2 wires  
Display  
Temperature adjustment buttons  
Backlight  
button  
2
.3 Connecting the Heating System  
NOTE:  
No polarity  
to observe.  
Display  
Load  
2
.4 Unoccupied Mode Input (TH148ELE only)  
TH148ELE has an input that can be used to  
lower the temperature when the house is  
unoccupied. You can connect an Aube’s  
CT240 telephone controller (optional) or  
another remote control system.  
Appears when the  
setpoint is displayed  
Temperature  
Unoccupied mode  
Heating is On  
When the thermostat receives a 12-VDC sig-  
nal, it switches to the unoccupied mode where  
the setpoint programmed for that mode is  
used (see section 4). When the signal is  
removed, the thermostat returns to the previ-  
ous mode.  
Low battery  
NOTE: No polarity  
to observe.  
2
.
Installation  
o
IN ORDER TO AVOID ANY RISK OF ELECTRIC SHOCK, CUT  
POWER TO THE HEATING SYSTEM.  
2.5 Installing the Batteries  
Note: The installation must be performed by an electrician.  
2.1 Guidelines  
After removing the old thermostat:  
Identify and label each wire (with the corresponding letter on the  
wire terminal) before removing them from the terminals.  
Right after the batteries are installed, the thermostat performs a  
series of tests for approximately 5 seconds.  
If necessary, strip the end of each wire (maximum of 6 mm).  
For a new installation:  
2
.6 Completing the Installation  
Choose a location approximately 1.5 m above the floor and on an  
inside wall.  
Avoid draughty areas (top of staircase, air outlet, etc.), dead air  
spots (behind doors), direct sunlight or areas near concealed  
pipes or chimneys.  
TH147E & TH148ELE  
400-147-017-C  
2008-01-08  
1/2  
href="
3
.
5.  
Operation  
Technical Specifications  
r
p
Power supply: 2 LR6 (1.5V) Alkaline batteries  
Maximum load: 5 A (resistive), 0.95 A (inductive) @ 240 VAC  
Power across UN terminals: 20 mA @ 12 VDC  
Setpoint range: 5 to 28°C  
3
.1 Backlight  
The display illuminates for 12 seconds when the backlight button or  
any other button is pressed.  
3
.2 Displaying the Temperature  
Display range: -10 to 50°C  
The actual (measured) temperature is normally displayed. To view  
the setpoint temperature, press once on either of the buttons.  
icon, will be displayed for the next 5  
Display resolution: 0.5°C  
Accuracy: ± 0.5°C  
The setpoint, along with the  
seconds.  
Cycle length: 10, 12, 15, 20 or 30 minutes (programmable)  
Conformity: IEC60730-1  
3
.3 Setting the Temperature  
Storage temperature: -20 to 50°C  
Dimensions: 127 mm x 75 mm x 28 mm  
Press one of the  
played.  
buttons until the desired temperature is dis-  
6
.
3
.4 Unoccupied Mode (TH148ELE only)  
Warranty  
;
To place the thermostat in unoccupied mode, see section 2.4. When  
the thermostat is in this mode, the unoccupied mode setpoint is used  
Aube warrants this product, excluding battery, to be free from defects in the  
workmanship or materials, under normal use and service, for a period of three  
(3) years from the date of purchase by the consumer. If at any time during the  
warranty period the product is determined to be defective or malfunctions,  
Aube shall repair or replace it (at Aube's option).  
(see section 4) and the  
icon is displayed.  
Temporary Bypass  
If you modify the setpoint temperature when the thermostat is in  
unoccupied mode, the new setpoint will be used for the next 2  
hours. Afterwards, the thermostat will return to the unoccupied  
If the product is defective,  
i) return it, with a bill of sale or other dated proof of purchase, to the place  
(
from which you purchased it, or  
mode setpoint. The  
icon flashes during the bypass.  
(ii) call Aube Technical Support at 33 (0) 1 34 07 99 00. Technical Support  
will make the determination whether the product should be returned to  
the following address: 10 rue Ampère, 95500 Gonesse, France, or  
whether a replacement product can be sent to you.  
3
.5 Low-battery Indicator  
An icon appears when the batteries need replacement.  
This icon will flash for 60 days, afterwards the thermo-  
stat will cut power to the heating system. The icon dis-  
appears once the batteries are replaced.  
This warranty does not cover removal or reinstallation costs. This warranty  
shall not apply if it is shown by Aube that the defect or malfunction was  
caused by damage which occurred while the product was in the possession of  
a consumer.  
Aube's sole responsibility shall be to repair or replace the product within the  
terms stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR  
DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUEN-  
TIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY  
BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER  
FAILURE OF THIS PRODUCT. Some regions do not allow the exclusion or  
limitation of incidental or consequential damages, so this limitation may not  
apply to you.  
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON  
THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES,  
INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS  
FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-  
YEAR DURATION OF THIS WARRANTY. Some regions do not allow limita-  
tions on how long an implied warranty lasts, so the above limitation may not  
apply to you.  
Note: The setpoint temperature is unaffected when the batteries are  
removed from the thermostat.  
4
.
Configuration  
q
n Press the backlight button until the configuration menu appears  
3 seconds).  
(
o To go to the next parameter (menu item), press the backlight but-  
ton (1 second).  
p To modify a parameter, press  
.
q Repeat steps 2 and 3 if necessary.  
This warranty gives you specific legal rights, and you may have other rights  
which vary from region to region.  
If you have any questions concerning this warranty, please write Aube, 705  
Montrichard, Saint-Jean-sur-Richelieu, Quebec J2X 5K8 Canada.  
r To end, press the backlight button until the configuration menu  
disappears (3 seconds).  
DESCRIPTION  
DEFAULT  
SELECTIONS  
7
.
Pump protection 1  
Unoccupied mode temperature 2  
Off  
On or Off  
Technical Assistance  
For any questions regarding the product installation or operation,  
contact our technical support team at  
1
0°C  
4
5°C to 28°C  
(TH148ELE only)  
Number of cycles per hour 3  
Tel.: 33 (0) 1 34 07 99 00  
Fax: 33 (0) 1 34 07 99 19  
Email: advaube@comintes.com  
2, 3, 4, 5 or 6  
1
When pump protection is On, the thermostat will activate the heating sys-  
tem for 15 seconds if it has not been activated for the past 24 hours.  
2
See section 3.4.  
For more information on our products, visit us at  
3
The corresponding cycle lengths are: 2=30 min., 3=20 min., 4=15 min.,  
www.aubetech.com  
5
3
=12 min., 6=10 min. The corresponding cycle lengths are: 2=30 min.,  
=20 min., 4=15 min., 5=12 min., 6=10 min. Select the cycle according to  
the type of heating: gas boiler <30kW: 10 minutes; oil boiler: 20 minutes  
TH147E & TH148ELE  
400-147-017-C  
2008-01-08  
2/2  

Honeywell AC 140 7 Thermostat User Manual

Honeywell CT53 Thermostat User Manual

Honeywell T8501D Thermostat User Manual

White Rodgers 90 Thermostat User Manual

Honeywell RTH7000D1049 Thermostat User Manual

Honeywell V4944 Thermostat User Manual

Honeywell TH2110D Thermostat User Manual

Honeywell TH115 AF GA Thermostat User Manual

White Rodgers 1F70 Thermostat User Manual

White Rodgers 1.00E+78 Thermostat User Manual