THE ROUND® CREATIVE SERIES Y460A2003 THERMOSTAT
—
Let the system operate through the ammeter for
at least one minute before taking a reading.
Record the reading here ______________ .
Reconnect the W wire to the W terminal.
9
CHECK OUT THE SYSTEM
—
Heating
❑
Turn down the temperature setting to the lowest
❑
Move the heat anticipator indicator to match the
number you recorded in Step 3 or in Step 7.
point. Move the System switch to Heat. Raise the
temperature setting above room temperature; the
heating equipment should start. Lower the
temperature setting below room temperature; the
heating system should stop.
NOTE: Hot water and steam systems require you to
multiply the current rating times 1.3. For elec-
tric heat systems, add the fan relay current,
usually 0.2A to 0.4A.
Cooling
❑
Snap the cover ring over the thermostat dial.
CAUTION
8
SET THE TEMPERATURE
Equipment Damage Hazard.
Can cause permanent damage to the
compressor or other equipment.
To avoid possible compressor damage, allow
the compressor to remain off for five minutes
before restarting.
❑
Turn the transparent dial until the desired point on
the setting scale is aligned with the pointer, as shown
in the illustration.
IMPORTANT:
During a call for heat or cool, an electrical
To avoid possible equipment damage, do not
operate cooling when the outside temperature is
below 50°F (10°C).
spark can be seen through the colored
decorator cover ring. Do not be alarmed;
this is normal operation for a mercury
switch.
See equipment manufacturer instructions.
Set Subbase Switch
CAUTION
Equipment Damage Hazard.
Can cause permanent damage to the
compressor.
Do not rotate the thermostat dial back and forth
just to observe the electrical spark; observe the
compressor five-minute minimal-off period.
CAUTION
Can cause permanent damage to the
Equipment Damage Hazard.
compressor.
Do not rotate the thermostat dial back and forth
just to observe the electrical spark; observe the
compressor five-minute minimal-off period.
❑
Turn up the temperature setting to the highest point.
Move the subbase System switch to Cool. Lower the
temperature setting below the room temperature; the
cooling equipment should start. Raise the tempera-
ture setting above the room temperature; the cooling
system should stop.
❑
❑
To operate the heating system, set the subbase
System switch to Heat. To operate the cooling
system, set the subbase System switch to Cool. Set
it to Off if you want neither heating or cooling.
Set the Fan switch to On for continuous fan
operation or to Auto for fan operation during heating
or cooling cycles.
WARRANTY
TEMPERATURE
SETTING
Honeywell warrants this product, excluding battery, to be free
from defects in the workmanship or materials, under normal
use and service, for a period of one (1) year from the date of
purchase by the consumer. If, at any time during the warranty
period, the product is defective or malfunctions, Honeywell
shall repair or replace it (at Honeywell’s option) within a rea-
sonable period of time.
If the product is defective,
i. return it, with a bill of sale or other dated proof of pur-
chase, to the retailer from which you purchased it, or
ii. package it carefully, along with proof of purchase
(
including date of purchase) and a short description of
the malfunction, and mail it, postage prepaid, to the fol-
lowing address:
THERMOMETER
M13419
Honeywell Inc.
Return Goods Department
1
050 Berkshire Lane
Plymouth, MN 55441-4437
This warranty does not cover removal or reinstallation costs.
This warranty shall not apply if it is shown by Honeywell that
the defect or malfunction was caused by damage which
occurred while the product was in the possession of a
consumer.
69-1358
4