Lux Products PSP711TS Thermostat User Manual

Home

href="
5.2. PROGRAMMING THE UNIT  
To ease reprogramming later, record your thermostat’s  
PSP711TS SERIES  
INSTALLATION AND OPERATING INSTRUCTIONS  
programs and settings in the table provided below.  
HEAT  
COOL  
DAY  
PERIOD  
SMART TEMP ELECTRONIC THERMOSTAT  
TIME TEMP. TIME TEMP.  
MORN  
DAY  
THURS  
EVE  
HEAT  
COOL  
DAY  
PERIOD  
NIGHT  
MORN  
DAY  
TIME TEMP. TIME TEMP.  
Easy as  
MORN  
DAY  
MON  
FRI  
SAT  
SUN  
123  
EVE  
Installs Easily  
EVE  
Set Day & Time  
Choose Heat or Cool  
NIGHT  
MORN  
DAY  
NIGHT  
MORN  
DAY  
Thank you for your confidence in our product. To obtain the best  
IMPORTANT!  
results from your investment, please read these instructions and  
acquaint yourself with your purchase before installing your new  
thermostat. Then follow the installation procedures, one step at a  
time. This will save you time and minimize the chance of  
damaging the thermostat and the systems it controls.  
Please read all instructions carefully before beginning  
TUES  
WED  
EVE  
EVE  
installation. Save them for future reference.  
NIGHT  
MORN  
DAY  
Before removing any wiring from your existing thermostat,  
its wires must be labeled with their terminal designations.  
Ignore the color of the wires since they may not comply  
NIGHT  
MORN  
DAY  
These instructions may contain information beyond that required  
for your particular installation. Please save for future reference.  
with any standard.  
EVE  
EVE  
NIGHT  
NIGHT  
1.  
2.  
3.  
FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
COMPATIBILITY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
TOOLS REQUIRED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
LOCATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
REMOVING THE OLD THERMOSTAT . . . . . . . . . . . . . . . . . . . . . . .  
MOUNTING THE PSP711TS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
CONNECTING THE WIRES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2
2
2
2
2
3
3
3
4.11. TEMPORARY TEMPERATURE OVERRIDE. . . . . . . . . . . . . . . . . . .  
4.12. TEMPERATURE HOLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
5
5
5
5
5
6
6
6
6
7
7
7
7
7
7
7
7
7
8
8
8
8
8
8
8
5.  
PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
DEFAULT ENERGY STAR® TEMPERATURE PROGRAMS. . . . . .  
PROGRAMMING THE UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3.1.  
3.2.  
3.3.  
3.4.  
3.5.  
3.6.  
3.7.  
4.  
5.1.  
5.2.  
JUMPER AND SWITCH POSITIONS  
5.2.1. COPY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6.  
ADVANCED FEATURES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
FILTER USAGE MONITOR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SWING SETTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
TEMPERATURE CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
ENERGY USAGE MONITOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
PROGRAM LOCK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
OPTION  
SWITCHES  
ON  
C
RH RC  
O
B
G
Y W  
6.1.  
6.2.  
6.3.  
6.4.  
6.5.  
1
2 3 4  
WIRING DIAGRAMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-11  
COMPLETING YOUR INSTALLATION. . . . . . . . . . . . . . . . . . . . . . .  
OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SYSTEM MODE SWITCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
FAN MODE SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
UP/DOWN ARROW CHANGE KEYS . . . . . . . . . . . . . . . . . . . . . . . .  
3
4
4
4
4
4
4
4
4
4
4
4
4
4
4
5
5
GAS/ELECTRIC  
JUMPER  
4.1.  
4.2.  
4.3.  
HARDWARE  
RESET  
6.5.1. TO SET CODE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6.5.2 TO LOCK SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6.5.3. TO UNLOCK SETTINGS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SOFTWARE  
RESET  
4.3.1. TEMPERATURE ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4.3.2. CHANGING OTHER SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
GAS  
7.  
SETUP OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
THE DISPLAY FORMAT 12/24 SWITCH #1. . . . . . . . . . . . . . . . . .  
SMART RECOVERY SWITCH #2 . . . . . . . . . . . . . . . . . . . . . . . . . . .  
TEMPERATURE DISPLAY FORMAT F°/C° SWITCH #3 . . . . . . .  
5 MIN/2 MIN MINIMUM RUN TIME SWITCH #4. . . . . . . . . . . . .  
REPOSITIONING SWITCHES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
GAS/ELECTRIC JUMPER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
BATTERIES AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
TECHNICAL ASSISTANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
OPTION SWITCH  
POSITION TABLE  
12hr SR=OFF  
24hr SR=ON  
F
C
3
5min  
2min  
4
7.1.  
7.2.  
7.3.  
7.4.  
7.5.  
7.6.  
8.  
ELEC  
4.4.  
4.5.  
4.6.  
4.7.  
NAVIGATION KEYS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
DISPLAY ILLUMINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
AUDIBLE BEEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
ICONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
U4  
1
2
BATTERY  
COMPARTMENT  
--  
+
4.7.1. FLAME ICON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4.7.2. SNOWFLAKE ICON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4.7.3. LOW BATTERY ICON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4.8.  
4.9.  
HARDWARE RESET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SOFTWARE RESET. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
REAR OF THERMOSTAT WITH COVER REMOVED  
9.  
10.  
4.10. SETTING THE TIME AND DAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only.  
Energizer® is a registered trademark of Eveready Battery Company, Inc.  
WARNING: Use Energizer® or DURACELL®  
DURACELL® is a registered trademark of The Gillette Company, Inc.  
Alkaline Batteries Only.  
Energizer® is a registered trademark of Eveready Battery Company, Inc.  
DURACELL® is a registered trademark of The Gillette Company, Inc.  
G
12  
Mt. Laurel, New Jersey 08054, USA www.luxproproducts.com  
43379  
href="
PROGRAM PERIOD  
Do not install it where there are unusual heating  
7. Press up on the  
thumb latch at the  
bottom of thermostat  
and separate the  
conditions, such as: in direct sunlight; near a  
lamp, radio, television, radiator, register, or  
fireplace; near hot water pipes in a wall; near a  
stove on the other side of a wall.  
DAY OF  
WEEK  
body from its base.  
Do not locate in unusual cooling conditions,  
8. Hold the base against the wall. Route the wires  
through the hole below the terminal block.  
Position the base for best appearance (to hide any  
marks from an old thermostat). Attach the base to  
the wall with the two screws provided.  
TIME  
such as: on a wall separating an unheated room;  
or in a draft from a stairwell, door, or window.  
Do not locate in a damp area. This can lead to  
corrosion that will shorten thermostat life.  
Do not locate where air circulation is poor, such  
NOTE:  
as: in a corner or an alcove; or behind an open  
door.  
If you are mounting the base to a soft material like  
plasterboard or if you are using the old mounting  
holes,  
TEMPERATURE  
Do not install the unit until all construction work  
MODE SWITCH  
the screws may not hold. Drill a 3/16-in. (4.8mm)  
hole at each screw location, and insert the plastic  
anchors provided. Then mount the base as described  
below.  
and painting has been completed.  
CAUTION:  
• Read instructions carefully before removing any  
wiring from existing thermostat.  
LIGHT  
BUTTON  
PSP711TS  
• Wires must be labeled before they are removed.  
3.5. CONNECTING THE WIRES  
FAN SWITCH  
• Do not allow wires to touch each other or parts on  
9. Loosen wire clamp screws just  
enough to slide wire under the  
black top part of the clamp.  
thermostat.  
1. FEATURES  
Ask your dealer for other LUX thermostats to  
control those systems.  
3. INSTALLATION  
• When removing wires from their terminals, ignore the  
color of the wires since they may not comply with any  
standard.  
Extra Large Hybrid Touch Screen Display  
10. Using your label, and  
Audible Touch Confirmation  
EL Display Illumination  
Elegant Design  
diagrams below determine  
Please read all instructions carefully before  
appropriate wiring for you system.  
3.3. REMOVING THE OLD THERMOSTAT  
beginning installation.  
11. If you are unsure or need assistance, call the  
LUX Technical Assistance Dept. (see technical  
assistance.)  
1. Switch electricity to the furnace and air  
conditioner OFF; then proceed with the following  
steps.  
7 Day Programming  
WARNING:  
Energy Star® Compliant  
4 Periods Per Day  
• Your thermostat is a precision instrument. Please  
handle it with care.  
12. Slide proper wire between the brass back and  
Battery Free Memory For All Programs And  
2. Remove cover from old thermostat. Most are  
snap-on types and simply pull off. Some have  
locking screws on the side; these must be  
loosened.  
3. Note the letters printed near the terminals.  
Attach labels (enclosed) to each wire for  
identification. Remove and label wires one at a  
time. Make sure the wires do not fall back inside  
the wall.  
All wiring must conform to local codes and  
black top clamp.  
Settings  
ordinances.  
Temporary Temperature Override  
13. Tighten each screw securely.  
3.6. WIRING DIAGRAMS  
See Pages 9-11 for diagrams.  
• Turn off electricity to the appliance before installing or  
servicing thermostat or any part of the system. Do not  
turn electricity back on until work is completed.  
Temperature Hold  
Keyboard Lockout  
F/C Temperature Display  
• This thermostat is designed for use with 24 volt and  
millivolt systems. The thermostat should be limited to a  
maximum of 1.5 amps; higher amperage may cause  
damage to the thermostat.  
• Do not short (jumper) across electric terminals at  
control on furnace or air conditioner to test the system.  
This will damage the thermostat and void your warranty.  
3.7. COMPLETING YOUR INSTALLATION  
12/24 Hr Clock Display  
Adjustable Temperature Differential / Cycle Rate  
Temperature Calibration  
14. Install two(2) Energizer or DURACELL "AA"  
size alkaline batteries at this time. For  
instructions, see "BATTERIES &  
MAINTENANCE".  
5/2 minute selectable minimum Run/Off time  
4. Loosen all screws on the old thermostat and  
provides short cycle and compressor protection  
remove it from the wall.  
CAUTION:  
15. Initially, your thermostat will display "SUN  
12:00 AM". To correct the display, refer to  
"Setting the DAY and TIME" in the "OPERATING  
INSTRUCTIONS" section of this manual.  
16. Install your PSP711TS on its base. To do this  
hang the top of the unit by the tabs on the base,  
then snap the bottom of the unit into place. Do not  
use unnecessary force. If the body does not snap  
into place easily, remove the body, re-hang it from  
the tabs and try again.  
3.4. MOUNTING THE PSP711TS  
• The PSP711TS is protected against normal static  
electric discharges. However, in extremely dry weather  
you should touch a grounded metal object before the  
PSP711TS to minimize the risk of causing damage to  
the unit.  
3.1. TOOLS REQUIRED  
5. Strip insulation leaving 3/8 in. (9.5mm) bare  
G
#1 Phillips screwdriver (small)  
wire ends and clean off any corrosion.  
G
Drill with 3/16-in. (4.8mm) bit  
6. Fill wall opening with non-combustible  
insulation to prevent drafts from affecting the  
thermostat.  
G
Wire stripper/cutter  
3.2. LOCATION  
• Your thermostat is a precision instrument. Please  
handle it with care.  
On replacement installations, mount the new  
thermostat in place of the old one unless the  
conditions listed below suggest otherwise. On new  
installations, follow the guidelines listed below.  
CAUTION:  
2. COMPATIBILITY  
Be careful not to drop the body or disturb electronic  
parts. Leave the cover closed while the body is being  
removed from the base.  
The PSP711TS can be used with most 24 volt gas,  
oil or electric heating and air conditioning systems,  
single stage heat pumps or gas millivolt heating  
systems. It cannot be used with 3 wire zone  
valves, 120V systems, or multistage systems.  
17. Turn the power back on to your heating  
Locate the thermostat on an inside wall, about 5  
and/or air conditioning system.  
ft. (1.5m) above the floor, in a room that is used  
often.  
2
3
href="
18. Verify that the system and its fan are  
operating properly. When set to a high  
4.3.2. CHANGING OTHER SETTINGS  
4.9. SOFTWARE RESET  
OVERRIDE will be automatically canceled at the  
start of the next program period.  
If there are many choices for a value, usually that  
setting will automatically advance by holding one  
of the arrow keys. Some settings though, must be  
changed one touch at a time.  
This reset is disabled while the touchscreen is  
temperature, the heating system should provide  
warm air after a short time. Likewise a cooling  
system should provide cool air after a short time.  
Usually sound from the furnace and air  
locked. When activated it will reset all  
OVERRIDE will be cancelled if the set  
programmable values and settings including the  
lock code and clock, to their default values. Then  
option switch positions will be read before  
resuming normal operation. Record your settings  
and programs before pressing this button.  
temperature is adjusted to its programmed value  
or if the units mode is changed.  
4.4. NAVIGATION KEYS  
4.12. TEMPERATURE HOLD  
conditioning units can be heard while they are  
running. The rush of moving air should be heard  
within a short time after either has been started.  
MENU: Touch this key to begin viewing available  
HOLD may be used for manual temperature  
control. It is the simplest means to set and  
maintain a fixed temperature in Heat or Cool,  
without concern for programming.  
menus.  
NOTE:  
SCROLL: Use this key to see the available menu  
NOTE:  
Take care not to inadvertently press the SOFTWARE  
RESET button while programming your unit.  
choices.  
If you have an electric heat system and the blower  
does not operate after installation, see figure in  
Section 7 to find the electric/gas heat jumper on the  
back of the body. Move the jumper to the ELEC  
position.  
Touching HOLD toggles the unit into or out of  
YES: Touch this key to enter a menu. When  
present on a menu, touching this key accepts any  
setting changes you have made.  
the hold mode with the current status indicated in  
the display. In HOLD adjust temperature as  
desired.  
• Performing a SOFTWARE RESET will reprogram all  
software settings to their default values.  
• Copy your programs into the blank chart provided on  
page 12 before using SOFTWARE RESET to assist  
reprograming.  
NOTE:  
Temperature settings will only change manually  
Neglecting to accept changes by touching this key  
when present, will leave the unit at its previous  
setting.  
while HOLD is active. To clear hold, touch HOLD  
19. Your installation is now complete.  
again.  
4. OPERATING INSTRUCTIONS  
4.10. SETTING THE DAY AND TIME  
5. PROGRAMMING  
The PSP711TS displays the current time and the  
room temperature. It also displays the day of the  
week and the current program period, MORN,  
DAY, EVE, or NITE. Temperature is indicated near  
the center of the display, and time is indicated on  
the left. Setting and program changes can be  
made with the thermostat body on the wall, or  
removed from its base plate.  
EXIT  
operating screen.  
:
Touch this key to return to the main  
SET DAY: Touch displayed DAY, advance with UP  
The PSP711TS provides four independent  
programming periods per day. Heat and Cool are  
programmed separately. You can use the default  
programs or alter them to suit your schedule.  
arrow.  
4.5. DISPLAY ILLUMINATION  
Touch displayed DAY again to return to main  
screen.  
SET TIME: Touch displayed time, set with UP or  
DOWN arrows. Touch displayed time again to  
return to main screen.  
Press the light bulb button at the lower right  
corner of the body to illuminate the display. It will  
remain illuminated for 15 seconds. Touching a  
field in the screen extends illumination time.  
5.1. DEFAULT ENERGY STAR® TEMPERATURE  
PROGRAMS  
To review the programs select Heat or Cool mode,  
touch MENU and then use SCROLL to see HEAT  
or COOL PROGRAM. Touch YES to enter HEAT or  
COOL PROGRAM. Use NEXT to step through each  
period and its set temperature. You can use the  
built-in programs as shown, or change them as  
you wish. Touch EXIT to return to the main display.  
Each day is divided into four periods. Each period  
has its own starting time and temperature.  
DAY and TIME may also be set from their menu as  
4.6. AUDIBLE BEEP  
4.1. SYSTEM MODE SWITCH  
follows:  
The PSP711TS will emit an audible beep to  
acknowledge that a field in the screen has been  
touched.  
The SYSTEM MODE SWITCH has three positions  
HEAT, OFF and COOL. Each sets the corresponding  
operating mode. In the winter, set the system  
switch to HEAT to control your heating system. In  
the summer, set the switch to COOL to control  
your air conditioner. In spring and fall or when the  
windows are open, you can set the switch to OFF.  
When thermostat is in the OFF position, neither  
HEAT or COOL programs will run.  
Touch MENU. You should see Set Day/Time  
displayed.  
4.7. ICONS  
4.7.1 FLAME ICON  
Touch YES and day of the week will flash.  
Touch UP ARROW to advance to set the day.  
Touch YES to accept displayed week day and  
In HEAT mode a FLAME icon will be  
visible to the right of the current room  
temperature. While heating is active, the  
FLAME will flash.  
advance to SET TIME. Or touch NEXT to advance  
to set current time without accepting changes.  
Time will be flashing.  
The default programs are given in the following  
table:  
4.2. FAN MODE SWITCH  
Touch UP/DOWN ARROW to set the current  
4.7.2. SNOWFLAKE ICON  
PERIOD  
HEAT MODE  
COOL MODE  
The fan switch has two positions; AUTO will only  
run your system’s fan as required for heating and  
cooling. ON runs your system’s fan continuously.  
0
0
0
0
time of day.  
Morning 6:00 AM 70 F (21 C) 6:00 AM 78 F (26 C)  
Day  
Evening 6:00 PM 70 F (21 C) 6:00 PM 78 F (26 C)  
Night  
In COOL mode a SNOWFLAKE icon will  
be visible to the right of the current room  
temperature. While cooling is active, the  
SNOWFLAKE will flash.  
0
0
0
0
Touch YES to accept displayed time.  
8:00 AM 62 F (17 C) 8:00 AM 85 F (29 C)  
0
0
0
0
Touch EXIT to return to the main screen, or  
0
0
0
0
10:00 PM 62 F (17 C) 10:00 PM 82 F (28 C)  
4.3. UP/DOWN CHANGE ARROW KEYS  
touch NEXT to rotate back to SET THE DAY.  
While operating the PSP711TS there will often be  
two arrow keys visible (just to the right of the  
temperature) one pointing up and the other  
pointing down. They are used to adjust  
Pressing the S. RESET button restores these  
heating and cooling programs and all other default  
settings.  
4.7.3 LOW BATTERY ICON  
4.11. TEMPORARY TEMPERATURE OVERRIDE  
When the Low Battery level has been  
Temporary temperature override allows you to  
change the current Set Temperature in Heat or  
Cool until the next program period without  
changing your temperature control programs.  
reached, the battery icon will appear.  
REPLACE  
It will disappear only when fresh  
5.2. PROGRAMMING THE UNIT  
temperatures and change other settings.  
4.3.1. TEMPERATURE ADJUSTMENT  
batteries have been installed.  
You can change any preset times and/or  
temperatures to suit your schedules for HEAT and  
COOL during each period of each day of the week.  
A blank programming chart is provided for you to  
record your temperature settings in that chart  
(See PAGE 12).  
Touch displayed temperature; the screen will  
4.8. HARDWARE RESET  
Touch the displayed temperature once then touch  
the UP/DOWN arrow key; it adjusts the flashing  
set temperature by one degree in the associated  
direction. Holding the key will automatically  
advance the setting in the associated direction. For  
simple operation see HOLD.  
flash your SET TEMPERATURE. UP/DOWN arrows  
will become visible.  
This button will unlock the touchscreen and read  
option switch positions before the unit resumes  
normal operation. Programs and other settings  
will be maintained. See jumper and switch  
positions figure on Page 12.  
Use UP/DOWN arrows to change the  
temperature setting while it is flashing. OVERRIDE  
will be indicated at the top of the display.  
4
5
href="
Set the mode switch to HEAT to program the  
convenient for you.  
5.2.1. COPY  
COPY will copy the previous days programs into  
the current day and advance the thermostat to the  
beginning of next day.  
Use UP/DOWN arrows to adjust.  
Touch EXIT to return to main display.  
Touch YES to accept new code; ENTER OLD  
CODE will be visible.  
Touch EXIT to return to main display.  
6.5.2. TO LOCK SETTINGS  
Touch OPEN LOCK SYMBOL on display LOCK  
KEY? will appear.  
unit for controlling your heater. Set the mode  
switch to COOL to program the unit for controlling  
your air conditioner.  
6.3. TEMPERATURE CALIBRATION  
From the main menu touch MENU.  
SCROLL to CAL TEMP.  
Touch YES. CAL TEMP will be visible and  
Touch MENU  
.
Use SCROLL to advance to SET/REVIEW HEAT  
6. ADVANCED FEATURES  
6.1. FILTER USAGE MONITOR  
PROGRAMS or SET/REVIEW COOL PROGRAMS.  
Touch YES. The display will now show a  
adjustment value will be flashing.  
Touch YES to begin scrolling through the HEAT  
or COOL settings.  
Use the UP/DOWN ARROW to change the  
CLOSED PADLOCK.  
Use UP/DOWN arrows to adjust offset value.  
Touch EXIT to return to the main screen.  
The FILTER MONITOR is used to help determine  
when your filter should be changed. It counts the  
hours of HEAT and COOL since it was last reset  
When the monitor limit is reached the CHANGE  
FILTER indicator will become visible. The default  
value of 720hrs is normally used for a 90 day filter.  
Other values are given in the following table.  
6.5.3. TO UNLOCK SETTINGS  
Touch the CLOSED PADLOCK. UNLOCK KEY? is  
6.4. ENERGY USAGE MONITOR  
flashing start time for MON MORN. One period  
ends at the start time of the next period. The  
beginning of a period may not be any closer to the  
beginning of the next period than one 15 minute  
increment.  
displayed.  
A timer in the unit records your system’s ON time  
for each mode of the current day, previous day,  
and cumulative total to let you see the effects of  
your temperature settings and weather conditions.  
Touch YES. ENTER LOCK CODE will be  
displayed.  
Hold UP/DOWN arrows to count to code  
number.  
Touch YES to accept the displayed start time  
and advance to program its set temperature.  
Use UP/DOWN ARROW to change the flashing  
temperature setting for MON MORN.  
Touch YES to accept the displayed temperature  
and advance to Set MON DAY start time.  
Use the UP/DOWN ARROW to change the  
flashing start time for MON DAY.  
Touch YES to accept the displayed value and  
advance to program temperature.  
Use UP/DOWN ARROW to change the flashing  
temperature setting for MON DAY.  
Touch YES to accept the displayed temperature  
and advance to Set MON EVE start time.  
Use the UP/DOWN ARROW to change the  
flashing start time for MON EVE.  
Touch YES to accept the displayed value and  
advance to program temperature.  
Use UP/DOWN ARROW to change the flashing  
temperature setting for MON EVE.  
Touch YES to accept the displayed temperature  
and advance to Set MON NITE start time.  
Use the UP/DOWN ARROW to change the  
flashing start time for MON NITE.  
Touch YES to accept the displayed value and  
advance to program temperature.  
Use UP/DOWN ARROW to change the flashing  
temperature setting for MON NITE.  
Touch YES to accept the displayed temperature  
and advance to Set TUE MORN start time.  
Continue programming for each day of the  
week.  
Select HEAT to monitor heating energy usage or  
FILTER LIFE IN DAYS SET COUNTER HOURS TO  
Touch YES to enter code. The OPEN LOCK  
COOL to monitor cooling usage.  
30  
60  
90  
240  
480  
720  
symbol will now be displayed in the display.  
To view ENERGY/USAGE  
If you forget your code and the touch screen is  
locked, perform a Hardware Reset to unlock it.  
With the touch screen unlocked, you may perform  
a Software Reset to reset the code to "000". See  
From the main menu touch MENU.  
SCROLL to ENERGY USAGE.  
Touch YES. The current day’s ENERGY USAGE  
To Reset Filter Counter And/Or Change The  
Counter Limit  
will be displayed.  
"Hardware Reset" and "Software Reset"  
.
At the main menu touch MENU.  
SCROLL to FILTER USAGE.  
Touch YES. Filter Usage Count will appear.  
Touch NEXT. RESET will show.  
Touch NEXT to view yesterday’s energy use.  
Touch NEXT to advance to total ENERGY usage  
7. SETUP OPTIONS  
There are Installation Option switches located  
inside the thermostat on the rear of its circuit  
board. They control the following:  
since the Monitor was last set to zero.  
Touch NEXT to display "000". Touching NEXT  
will toggle between the counter value and "000".  
Touch YES to accept the current display value  
as the counter value. Use "000" to effect a reset.  
Touch EXIT to return to the main screen.  
Touch YES to reset the counter and advance to  
7.1. TIME DISPLAY FORMAT 12/24 SWITCH #1  
the filter limit menu, or touch NEXT to advance to  
the filter monitor menu without resetting the  
counter. Limit Hours will be flashing.  
The position of this switch controls whether the  
time is displayed in 12 hour or 24 hour Military  
Time format.  
Use UP/DOWN arrows to change limit. Set the  
6.5. PROGRAM LOCK  
7.2. SMART RECOVERY SWITCH #2  
filter limit to "0" to disable the Filter Usage Monitor.  
The Program Lock allows the owners/operators to  
prevent unauthorized changes to the thermostat’s  
settings. When the thermostat is locked, a three  
digit code is set (000 to 999). That code must be  
re-entered before locked settings can be changed  
without performing a hardware reset of the unit.  
The status of the lock is indicated by an open or  
closed padlock icon.  
Smart Recovery allows your HVAC system to  
attempt to recover from a setback period and  
reach your desired comfort temperature set point  
by the beginning of your programmed comfort  
period. This option allows you to choose whether  
to use Smart Recovery.  
Touch YES to accept new count value and  
return to the filter counter menu. If a new limit is  
set, the filter counter will be reset automatically.  
Touch EXIT to return to main menu.  
6.2. SWING SETTING  
A thermostat works by turning your heating or  
cooling system on and off whenever the room  
temperature varies a certain number of degrees  
from the set-point temperature. This variation is  
the "swing." Your system should cycle on about 3  
to 6 times per hour. A smaller swing number  
increases the number of cycles, so room  
temperature is more constant. A larger swing  
number decreases the number of cycles, saving  
energy in most cases. To change the SWING value  
from the main menu:  
When enabled, Smart Recovery will initiate if:  
Recovery is from an evening setback to  
6.5.1. TO SET CODE  
morning comfort or day setback to evening  
comfort period.  
From the main menu touch MENU.  
SCROLL to SET KEYBOARD LOCK.  
Touch YES. ENTER OLD CODE and both open  
In Heat mode the temperature set point of the  
comfort period must be higher than the setback  
period.  
and closed padlock icons will be displayed. The  
default code is "000".  
In Cool mode the temperature set point of the  
Hold UP/DOWN arrows to count to code  
comfort period must be lower than the setback  
period.  
number.  
Touch EXIT to return to main screen.  
Touch YES. ENTER NEW CODE will appear.  
Hold UP/DOWN arrows to count to code  
The estimated Smart Recovery time must be  
Touch MENU.  
SCROLL to SWING VALUE.  
Touch YES. Adjust Swing Value will appear.  
TIP: Pressing Day, Time or Temperature while  
longer than 15 minutes for a Smart recovery to be  
initiated.  
programming will shift focus to that setting,  
allowing it to be edited in the order most  
number (Record Code Number).  
6
7
href="
Maximum Smart Recovery time is one hour.  
The Smart Recovery temperature set point must  
8. BATTERIES AND MAINTENANCE  
3.6. WIRING DIAGRAMS  
The PSP711TS requires batteries to operate your  
heating/cooling system. Replace the batteries  
when the battery REPLACE indicator appears in  
be achievable. If a desired smart recovery is  
repeatedly ignored by your thermostat. That is an  
indicator that you should modify your program so  
that the recovery can be achieved within the 1  
hour limit.  
the display or at least once a year  
.
2 + 3 WIRE HEATING SYSTEMS  
COOLING SYSTEMS  
1. To access your units batteries remove the unit  
from the wall by pressing up on the thumb latch at  
the bottom of thermostat and swinging the body  
up and away to remove it from the wall.  
JUMPER  
PROVIDED  
JUMPER  
PROVIDED  
A Smart Recovery may not be initiated for 48  
W
Y
G
B
O
RC RH  
C
W
Y
G
B
O
RC RH C  
hours after the units programs have been  
changed. This allows the unit to gather the data  
necessary to predict a Smart Recovery time.  
2. Remove the used batteries. See battery location  
and polarity in figure on Page 12.  
3. Install two new Energizer® or DURACELL®  
"AA" size alkaline batteries in the battery  
compartment. Observe the polarity marking  
shown in the compartment.  
7.3. TEMPERATURE DISPLAY FORMAT  
˚F/˚C SWITCH #3  
W
G
F
RH  
RC  
R
V
5
Y
G
F
RH  
R
The position of this switch controls whether the  
temperature is displayed in degrees ˚F or ˚C.  
4. Hang the top of the unit by the tabs at the top  
corners of the base, then snap the bottom of the  
unit into place. Do not use unnecessary force. If  
the body does not snap into place easily, remove  
the body, re-hang it from the tabs and try again.  
7.4. 5 MIN / 2 MIN MINIMUM RUN TIME  
SWITCH #4  
H
4
C*  
6
V
The position of this switch controls minimum  
length of time the thermostat must remain with  
Heat or Cool either ON or OFF before it will  
automatically switch to the alternate ON or OFF  
state. This feature prevents short cycling and  
provides compressor protection for cooling units.  
Choices are 2 or 5 minutes.  
NOTE: "G" WIRE IS  
OMITTED FOR  
2 WIRE SYSTEMS  
9. TECHNICAL ASSISTANCE  
If you have any problems installing or using this  
thermostat, please reread the instructions carefully  
or visit our online technical support at  
HEATING/COOLING SYSTEMS  
5 + 6 Wire 2 Transformers  
HEATING/COOLING SYSTEMS  
4 + 5 Wire 1 Transformers  
JUMPER  
REMOVED  
JUMPER  
PROVIDED  
7.5. REPOSITIONING SWITCHES  
www.luxproproducts.com. If you require  
assistance, please call our Technical Assistance  
number between 8:00 a.m. and 4:30 p.m. Eastern  
Standard Time, Monday through Friday. The  
number is (856) 234-8803.  
Use this table to determine the positions which  
W
Y
G
B
O
RC RH  
C
W
Y
G
B
O RC RH C  
correspond to the operation you prefer.  
12hr SR=OFF F 5min  
24hr SR=ON  
C
3
2min  
4
10. WARRANTY  
W
Y
C*  
6
G
F
B*  
O
RC RH  
R
W
Y
C*  
6
G
F
B*  
O
RH  
RC  
R
U4  
1
2
Limited Warranty: If this unit fails because of  
defects in materials or workmanship within one  
year of date of original purchase, LUX will, at its  
option, repair or replace it. This warranty does not  
cover damage by accident, misuse, or failure to  
follow installation instructions. Implied warranties  
are limited in duration to one year from date of  
original purchase. Some states do not allow  
limitations on how long an implied warranty lasts,  
so the above limitation may not apply to you.  
Please return malfunctioning or defective units to  
the participating retailer from which purchase was  
made, along with proof of purchase. Please refer  
to "Technical ASSISTANCE" before returning  
thermostat. Purchaser assumes all risks and  
liability for incidental and consequential damage  
resulting from installation and use of this unit.  
Some states do not allow the exclusion of  
This table is printed on the circuit board. To  
change a switch position move switch down or up.  
After settings have been changed with batteries  
installed, press the Hardware Reset (H.W. Reset)  
button on the rear of the unit's circuit board for  
changes to take effect. See jumper and switch  
positions figure on Page 12.  
H
4
V
H
4
V
5
5
7.6. GAS/ELECTRIC JUMPER  
WIRING DIAGRAM NOTES (APPLIES TO ALL DRAWINGS)  
* Verify whether “C”, “X” or “B” wires are connected to system common.  
* If “B” and “O” are both present, it is likely that “B” is a system common.  
* If a “B” wire in your system is a common, then connecting it to the “B” terminal may cause damage  
to your system.  
* If “Y” and “C” are both present, it is likely that “C” is a system common.  
* Use an optional common wire to allow the system to power your thermostat.  
In HEAT mode, the position of this jumper controls  
when the thermostat requests the system fan to  
run. In Gas mode the fan is normally controlled by  
the heating system itself. In Electric mode, the fan  
is controlled by the thermostat. See jumper and  
switch positions figure on Page 12.  
incidental or consequential damages, so the above  
exclusion may not apply to you. This warranty  
gives you specific legal rights and you may also  
have other rights which vary from state to state.  
Applicable in the U.S.A. only.  
8
9
href="
2 WIRE 24 VOLT/MILLIVOLT SYSTEM  
4 WIRE HEATING AND COOLING SYSTEM  
RC-RH  
JUMPER PROVIDED  
RC-RH  
JUMPER PROVIDED  
SYSTEM COMMON  
SYSTEM COMMON  
W
Y
G
B
O
RC RH  
C
W
Y
G
B
O
RC RH  
C
WIRING DIAGRAM  
NOTES  
(APPLIES TO ALL  
DRAWINGS)  
OPTIONAL  
OPTIONAL  
24 VOLT  
HEAT  
24 VOLT  
SYSTEM  
AC  
COMPRESSOR  
HEAT  
HEAT  
FAN  
TRANSFORMER  
TRANSFORMER  
120 VAC  
120 VAC  
* Verify whether “C”,  
“X” or “B” wires are  
connected to system  
common.  
* If “B” and “O” are  
both present, it is likely  
that “B” is a system  
common.  
* If a “B” wire in your  
system is a common,  
then connecting it to  
the “B” terminal may  
cause damage to your  
system.  
* If “Y” and “C” are  
both present, it is likely  
that “C” is a system  
common.  
5 WIRE SYSTEM HEATING AND COOLING - 2 TRANSFORMERS  
3 WIRE HEATING SYSTEM (3RD WIRE FOR FAN)  
RC-RH  
RC-RH  
JUMPER PROVIDED  
SYSTEM COMMON  
JUMPER REMOVED  
SYSTEM COMMON  
W
Y
G
B
O
RC RH  
C
W
Y
G
B
O
RC RH  
C
OPTIONAL  
24 VOLT  
COOL  
24 VOLT  
HEAT  
OPTIONAL  
24 VOLT  
HEAT  
HEAT  
COOLING  
FAN  
HEAT  
FAN  
TRANSFORMER  
TRANSFORMER  
TRANSFORMER  
120 VAC  
120 VAC  
120 VAC  
* Use an optional  
common wire to allow  
the system to power  
your thermostat.  
SINGLE STAGE HEAT PUMP SYSTEM  
RC-RH  
3 WIRE COOLING SYSTEM  
SYSTEM COMMON  
RC-RH  
JUMPER PROVIDED  
SYSTEM COMMON  
JUMPER PROVIDED  
W
Y
G
B* O* RC RH  
C
W
Y
G
B
O
RC RH  
C
ADD  
OPTIONAL  
JUMPER  
24 VOLT  
SYSTEM  
OPTIONAL  
HEAT  
CHANGEOVER  
HEAT  
CHANGEOVER  
COOL  
24 VOLT  
COOL  
FAN  
AC  
COMPRESSOR  
PUMP  
FAN  
TRANSFORMER  
TRANSFORMER  
120 VAC  
*"B" OR "O" BUT NEVER BOTH  
120 VAC  
10  
11  

Honeywell RTH2300B1012E1 Thermostat User Manual

Honeywell CG511A1000 Thermostat User Manual

Honeywell 69 1361 Thermostat User Manual

Honeywell CM61NG Thermostat User Manual

White Rodgers 1F85RF 275 Thermostat User Manual

White Rodgers 1F95W 71 Thermostat User Manual

Lux Products T10 1143SA Thermostat User Manual

Aprilaire 8348 Thermostat User Manual

White Rodgers 1F95 0671 Thermostat User Manual

Aube CT230 120GB Thermostat User Manual