Aube TH110 SP P Thermostat User Manual

Home

href="
MODEL TH110-SP-P  
SUMMARY  
OPTIONS SELECTION  
To change the temperature from °C to °F and back, maintain D button  
pressed down as RESET button is being pressed on and released.  
Then release D button.  
To change the time format from 24 hours to 12 hours and back,  
maintain H button pressed down as RESET button is being pressed  
on and released. Then release H button.  
TO SET TIME AND DAY  
Note:  
All cables and connections must conform to the local  
electrical code.  
Press on D, H and M buttons to adjust time and day.  
TO RECORD THE HEATING PROGRAMS  
WARNING: Special CO/ALR solderless connectors must be used when  
connecting with aluminum conductors.  
Set the operating mode to AUTO. Use the P button to select  
the program to be recorded or modified. Once the program is selected,  
use H and M buttons to set time and  
temperature setting.  
or  
to select  
2) Options selection  
Some options have been factory set. Those default settings are:  
The temperature is in °C and the time format is 24 hours.  
TO RECORD THE ECONO PROGRAMS  
Set the operating mode to ECONO. Use the P button to select  
the program to be recorded or modified. Once the program is selected,  
2
.1 Temperature displayed in °C or °F  
To change the temperature from °C to °F and back, maintain D button pressed  
down as RESET button is being pressed on and released.  
Then release D button.  
use D, H and M buttons to set time and day and  
temperature setting.  
or  
to select  
OPERATING MODES  
2
.2 Time format displayed in 24 hours or 12 hours  
To select an operating mode, use MODE button.  
To change the time format from 24 hours to 12 hours and back, maintain H  
button pressed down as RESET button is being pressed on and released. Then  
release H button.  
AUTO:  
MAN:  
runs the programs. shows temperature setting  
and can override temporarily your programming.  
or  
maintains the selected temperature.  
temperature setting.  
or  
changes  
3) Memory backup  
ECONO: maintains a temperature setting up to the user's  
In the event of a power failure, an internal circuit will maintain the program-  
pre-programmed day and time.  
temperature setting.  
or  
shows  
ming. An icon  
will be shown on the display. The display will stay on for 15  
minutes; beyond this period, the display will turn off. Only the time will have to  
be set if power failure is more than six hours. The thermostat will return to the  
same operating mode as set before the power failure.  
4
) First power-up  
When power is applied for the first time, the dis-  
play must show the day and hour as follows:  
0
:00 MO (Monday)  
The active operation mode is the framed MAN  
mode, the temperature setpoint is 20 °C (68 °F)  
and the ambiant temperature is displayed.  
If the display is different, maintain P button  
pressed down as RESET button is being pressed  
on and released. Then release P button.  
OPERATING MODES  
The thermostat displays the icon  
when the heating system is on and  
turns it off when the heating system is off.  
The TH110-SP-P thermostat has three (3) operating modes:  
AUTO, MAN and ECONO.  
INSTALLATION  
NOTE: The "Problems and Solutions" section at the end of this user's guide will  
They are selected through the MODE button. On display, the active mode is  
framed. The frame moves on to the next mode each time the MODE button is  
pressed on.  
help you to correct your problems during the installation.  
This thermostat has been designed to operate with any installation  
which has a RESISTIVE load not exceeding 4800 W (20 A) such as  
electric baseboards, radiant ceilings and floors, electric convectors,  
etc. It is not compatible with a low voltage controller used by a central  
heating system.  
The AUTOmatic mode runs in sequence (hourly)  
the programs recorded by the user.  
By pressing once on  
or  
, the display shows  
Electricians or experienced technicians should install the thermostat.  
the temperature setting. All subsequent pres-  
sures will override your programming up to the  
next program.  
This thermostat is designed to be used with a self-protected heating  
system equipped with thermal cut off and circuit breaker.  
To see the weekday and weekend programs, select  
the AUTO mode and press successively on P  
button to see the programs appear on the display.  
PARTS INCLUDED  
-
-
-
One (1) TH110-SP-P thermostat  
Two (2) 6-32 screws, 1 1/4 inches  
Three (3) solderless connectors  
TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER  
PANEL TO AVOID ELECTRIC SHOCK. Keep air vents of thermostat clean  
and free from obstructions.  
The MAN mode allows the user to override  
the programming.  
The first time the  
or  
is pressed on,  
1
) Connecting wires and mounting thermostat  
the temperature setting is displayed. For all  
subsequent times pressed on, the temperature  
setting will change 1 °C (1 °F).  
Connect the rear thermostat wires to the power supply and to the electric heater  
wires using solderless connectors for copper wires. See schematic diagram.  
Push the excess wire back into the electric box to prevent interference with the  
thermostat. Secure the thermostat using two (2) 6-32 screws 1 1/4 inches long.  
Once the thermostat is properly installed, return power to heating system.  
720-110522-A  
1/3  
href="
Press on P button again to record or modify  
weekday programs 2, 3 and 4 and weekend  
programs 1, 2, 3 and 4.  
The ECONO mode has two (2) programs in which the  
day, the time and the setpoint have to be pro-  
grammed. For instance, this operating mode can be  
used for a cottage installation where the user goes only  
on weekends.  
Use H, M,  
or  
buttons to modify  
the time and setpoint of programs.  
Program 1: Friday 3:00 PM, 20 °C (68 °F)  
Program 2: Friday 8:00 PM, 15 °C (59 °F)  
Programming is now completed. Press on R  
button or wait for the "automatic return"  
to exit the programming mode.  
The temperature will be maintained at 20 °C (68 °F)  
Friday from 3:00 PM to 8:00 PM, and maintained  
at 15 °C (59 °F) the rest of the week.  
Note: A program time left at -- -- : -- --  
is considered inactive.  
This gives you a comfortable temperature at your  
arrival and if you are not going to your cottage  
for the weekend, there will be only a minimal  
heating period.  
To reset a program, use P button to select the program, then press  
on MODE button.  
To review programs, press on P button successively to see the programs  
one after the other and make modifications if required.  
To see the ECONO programs, select the ECONO  
operating mode and press on P button successively  
to see programs 1 and 2 appear on the display. In  
ECONO mode, by pressing once on  
or  
, the  
4) Recording the ECONO programs  
display shows the temperature setting. All subsequent  
pressures will override your programming up to the  
next program.  
Select the ECONO mode.  
Press on P button once.  
PROGRAMMING  
The default values or the last recording  
of program 1 will be displayed.  
1
) Adjustment of time and day  
The default values are :  
Note: Select your OPTIONS before adjusting your time, because using the  
RESET button will set the time back to default 0:00 MO (Monday).  
20 °C (68 °F) and the time -- -- : -- -- .  
Example of setting: Thursday 8:15 AM  
Use D, H, M and or buttons to record  
the day, the time and the setpoint of program 1.  
Use D, H and M buttons to set the time. Once  
set, press on R button to exit the time and day  
adjustment mode.  
Press a second time on P button.  
The default values or the last recording  
of program 2 will be displayed.  
Note 1:  
icon is showing you that the time  
must be set.  
Use D, H, M and  
or  
buttons to modify  
Note 2:The thermostat has an automatic return.  
When such functions as time recording, pro-  
grams recording, etc., are not completed by  
pressing on return (R) button, the  
thermostat will automatically exit the mode  
after 60 seconds.  
the day, time and setpoint of program 2.  
Programming is now completed. Press on R  
button or wait for the "automatic return"  
to exit the programming mode.  
CHARACTERISTICS  
Model: TH110-SP-P  
Electronic programmable thermostat  
Supply: 240 VAC, 50/60 Hertz  
Load: 20 A maximum, 1 HP  
Power: 4800 W @ 240 VAC  
Power consumption (off): 860 mW  
Approvals: CSA NRTL/C  
Display range: 0 °C to 99 °C (0 °F to 99 °F)  
Setting range: 5 °C to 27 °C (40 °F to 80 °F)  
-
-
-
-
-
-
-
-
-
2
) Typical suggested programs  
This thermostat can store up to four (4) daily programs for weekdays and four  
4) daily programs for the weekend. Also, there is two (2) programs for the  
ECONO mode. To practice programming use the following example.  
(
Program number  
Time  
Temperature setting  
Weekday programs (Mon...Friday)  
- Storage: -20 °C to 50 °C (-4 °F to 120 °F)  
-
-
-
Temperature regulation: 1 °C (1 °F)  
Precision: ± 0.5 °C (1 °F) (4800 W)  
10 programs: 4 weekday programs, 4 weekend programs  
and 2 ECONO programs  
Program 1  
Program 2  
Program 3  
Program 4  
6:30 AM  
20 °C (68 °F)  
15 °C (59 °F)  
20 °C (68 °F)  
15 °C (59 °F)  
8:30 AM  
4:30 PM  
11:00 PM  
WARRANTY  
Weekend programs (Sat & Sun)  
Program 1  
Program 2  
Program 3  
Program 4  
7:00 AM  
20 °C (68 °F)  
15 °C (59 °F)  
20 °C (68 °F)  
15 °C (59 °F)  
AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY  
8:30 AM  
4:30 PM  
11:00 PM  
This product is warranted against material defects and workmanship in normal  
use for a period of one year, from the date of the original purchase from autho-  
rized dealers. During this period, AUBE technologies inc. will repair or replace  
the product with a new or of equivalent quality at AUBE'S option, without  
charge, any product proven defective in normal use.  
ECONO mode programs (weekend cottage)  
Program 1  
Program 2  
Friday 3:00 PM  
Friday 8:00 PM  
20 °C (68 °F)  
15 °C (59 °F)  
Warranty does not cover transportation costs. Nor does it cover a product sub-  
jected to misuse or accidental damage. This warranty does not cover the cost of  
installation, removal or reinstallation.  
3
) Recording the heating programs  
Select the AUTO mode.  
Press on P button once.  
This limited warranty is in lieu of all other warranties, obligations or liabilities  
expressed or implied by the company. In no event shall AUBE technologies inc.  
be liable for consequential or incidental damages resulting from installation of  
this product. Some states or provinces do not allow limitations on how long an  
implied warranty lasts, or the exclusion or limitation of incidental or conse-  
quential damages, so the above exclusions or limitations may not apply to you.  
This warranty gives you specific legal rights and you may also have other rights  
which vary from state to state.  
The default values or the last recording  
of program 1 will be displayed.  
The default values are:  
20 °C (68 °F) and the time -- -- : -- --.  
The days Monday to Friday are displayed to show  
that this program is for weekdays.  
The defective product and the original sale receipt must be returned  
to the original dealer or shipped pre-paid, insured and addressed to:  
Aube technologies inc. • Customer Service • 705, Av. Montrichard  
Iberville (Quebec) • J2X 5K8  
Press on H and M buttons until 6:30 is displayed.  
If you have any questions concerning the installation or programming of this  
product, please call our technical assistance at (450) 358-4600 for the Montreal  
area or 1-800-831-AUBE for outside area, Monday to Friday between  
Press on until 20 °C (68 °F) is displayed.  
or  
The first program is recorded.  
8
:30 AM and 5:00 PM Eastern time.  
ATTENTION: SEE TABLE PROBLEMS AND  
SOLUTIONS ON ATTACHED ANNEXE.  
720-110522-A  
2/3  
href="
PROBLÈMES ET SOLUTIONS  
PROBLÈMES  
CAUSES  
SOLUTIONS  
Pas d'affichage  
• Disjoncteur ouvert  
Vérifiez la présence  
Panne de courant prolongée  
plus de 15 minutes)  
du 240 Vca au thermostat  
(
Le thermostat perd l'heure  
mais pas la programmation  
• Panne de courant de longue  
durée (plus de 6 heures)  
Affichage de la température ambiante  
incorrect  
• Courant d'air à proximité  
• Éliminez les courants d'air  
Système de chauffage toujours  
en marche  
• Mauvaise installation  
• Vérifiez l'installation  
• Appuyez sur le bouton P  
pendant que vous enfoncez  
et relâchez le bouton RESET.  
Ensuite, relâchez le bouton P.  
Le thermostat affiche du chauffage mais le  
sytème de chauffage  
ne chauffe pas  
• Mauvaise installation  
• Panne de courant  
• Vérifiez l'installation  
• Vérifiez la présence  
du 240 Vca au thermostat  
(L’icone  
est allumée à l'écran.)  
Les programmes ne changent pas comme  
vous le souhaitez  
• Heures de programmation  
incorrectes  
• Vérifiez les heures actuelles  
de programmation  
Mauvais mode d'opération  
sélectionné  
(Attention au format AM  
et PM, AM n'est pas affiché)  
Assurez-vous que vous avez  
choisi le mode d'opération  
AUTO  
PROBLEMS AND SOLUTIONS  
PROBLEMS  
CAUSES  
SOLUTIONS  
No display  
• Circuit breaker is open  
• Check 240 Vac presence  
at the thermostat  
Power failure more than  
5 minutes  
1
The thermostat is loosing  
the time but not the programming  
• Power failure more than  
6 hours  
Room temperature shown is wrong  
• A draft is near the thermostat  
• Eliminate the draft  
• Check installation  
Heating system always on  
• Bad installation  
Maintain P button pressed  
down as RESET button is being  
pressed and released. Then release  
P button.  
The thermostat displays heating  
but heating system is not turned on  
• Bad installation  
• Power failure  
• Check installation  
• Check 240 Vac presence  
at the thermostat  
(Icon is shown on display)  
Programs do not change as you want  
• Incorrect programming hours  
Wrong programming mode selected  
• Check actual time  
in AM & PM as well  
as program times  
(AM is not displayed)  
Make sure operating mode  
is set to AUTO  
PROBLEMAS Y SOLUCIONES  
PROBLEMAS  
CAUSAS  
SOLUCIONES  
La pantalla no marca  
• Disyuntor abierto  
• Verifique la presencia de 240 Vca  
del termostato  
Corte de corriente eléctrica prolongado  
más de 15 minutos)  
(
El termostato pierde la hora pero  
no la programación  
• Pérdida de corriente de larga duración  
(más de 6 horas)  
Marca la temperatura ambiente incorrecta  
• Corriente de aire a proximidad  
• Elimine la corriente de aire  
• Verifique la instalación  
Sistema de calefacción siempre en marcha  
• Mala instalación  
Presione el botón P mientras  
presiona y suelta el botón RESET.  
Suelte enseguida el botón P.  
El termostato marca la calefacción pero el  
sistema de calefacción no calienta  
• Mala instalación  
• Corte de corriente eléctrica  
• Verifique la instalación  
• Verifique la presencia del  
240 Vca en el termostato  
(el icono se enciende en la pantalla)  
Los programas no cambian como usted  
desea  
• Horas de programación incorrectas  
• Selección de un modo de operación erróneo  
• Verifique las horas de programación  
actuales (Cuidado con el ciclo  
AM y PM, AM no aparece  
en pantalla)  
Asegúrese de haber elegido  
el modo de operación AUTO  
27/10/00  
720-110522-A  
3/3  

Carrier 33CSIRRCVR 01 Thermostat User Manual

Honeywell HE300 Thermostat User Manual

Honeywell TH8110U Thermostat User Manual

Honeywell MV100 Thermostat User Manual

Honeywell TL7230A Thermostat User Manual

Honeywell T775A Thermostat User Manual

Bryant T6 PHP Thermostat User Manual

White Rodgers 1F86 241 Thermostat User Manual

Honeywell CT70A Thermostat User Manual

Carrier TB NAC Thermostat User Manual