Aube TH110 Thermostat User Manual

Home

href="
TH110  
User Guide  
Programmable Thermostat  
1
.
3.  
Description  
Configuration  
p
The configuration switches are on the back of the thermostat. Default (factory)  
settings are inside the gray cells.  
n
Aube’s TH110 programmable thermostat can be connected to an electric  
heating system such as an electric baseboard, a radiant ceiling, a floor heat-  
ing system, an electric convector, etc. It is not compatible with a central heat-  
ing system.  
#
Configurations  
UP  
DN  
SW1  
SW2  
SW3  
SW4  
Not used  
Early Start a  
Time format  
Temperature format b  
Disable  
12-hour  
°F  
Enable  
24-hour  
°C  
Time and day  
a. Early Start can be used in Automatic mode only. When this function is  
enabled, the thermostat calculates the optimal time to start heating in  
order to obtain the desired temperature by the set time. The thermostat  
re-assesses the start time daily based on the previous day’s perfor-  
mance.  
Appears during the  
On/Standby  
switch  
setpoint display  
Temperature  
Operating  
mode icons  
Preset temperature  
icons  
b. If you change the temperature display format, the preset temperatures  
(
,
and ) will return to their default settings.  
Heating  
indicator  
To set the day  
To set the time  
4.  
Periods  
Power-up  
q
To program the schedule  
To skip a period  
Upon power-up, the thermostat is in manual mode ( ) and displays the  
Temperature  
preset buttons  
actual temperature.  
To select the  
operating mode  
n
o
Press the Hour and Min buttons to set the thermostat’s clock.  
Press the Day button to set the day.  
Temperature  
adjustment  
5
.
Temperature Setting  
r
*
Set the switch to Standby to cut power to the heater. This will not affect the time  
and temperature settings.  
Setpoint  
2
.
The thermostat normally displays the actual temperature. To view the set-  
Connection  
point, press the  
seconds.  
or  
button briefly. The setpoint will appear for the next 5  
or button until the desired temperature  
o
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER  
PANEL TO AVOID ELECTRICAL SHOCK.  
To change the setpoint, press the  
is displayed. To scroll faster, hold the button.  
The installation must be carried out by an electrician.  
Using a preset temperature  
All cables and connections must conform to the local electrical code.  
The thermostat has 3 preset temperatures:  
Special CO/ALR solderless connectors must be used when connecting  
with aluminum conductors.  
Comfort temperature  
Economy temperature  
Vacation temperature  
Install the thermostat onto an electrical box.  
Install the thermostat about 5 feet high, on an inside wall facing the  
heater.  
Icon  
Intended use  
Default setting  
Avoid locations where there are air drafts (such as the top of a staircase  
or an air outlet), dead air spots (such as behind a door), or direct sun-  
light.  
Comfort (when at home)  
21°C (70°F)  
Economy (when asleep or away from home)  
Vacation (during prolonged absence)  
16°C (62°F)  
10°C (50°F)  
Do not install the thermostat on a wall that conceals chimney or stove  
pipes.  
n
Connect the thermostat wires to the  
Power  
To use the Comfort or Economy temperature, press the  
respectively. The corresponding icon will be displayed.  
or button  
buttons simulta-  
2
40 V line and to the load using sold-  
erless connectors for copper wires.  
To use the Vacation temperature, press both  
neously. The icon will be displayed.  
and  
o
Push the excess wire back into the  
electrical box to prevent interference  
with the thermostat.  
B
R
Storing a preset temperature  
240 VAC  
B
B
To store the Comfort or Economy temperature:  
Set the desired temperature using the  
p
q
Secure the thermostat using two 6-32  
screws.  
R
or button. Press and hold  
60 HZ  
R
R
the appropriate button (  
or ) for approximately 3 seconds until the  
Return power to heating system.  
B
corresponding icon is displayed. Press the Mode button.  
NOTE: Always keep the thermostat's vents  
clean and unobstructed.  
Load  
To store the Vacation temperature:  
Set the desired temperature using the  
or button. Press and hold  
and buttons simultaneously for approximately 3 seconds  
icon is displayed. Press the Mode button.  
both  
until the  
TH110  
400-110-000-A  
2/6/05  
1/2  
href="
6
.
8.  
Operating Modes  
Troubleshooting  
u
Problems  
s
Automatic - The temperature is set according to the energy-saving  
schedule. To place the thermostat in this mode, press Mode until is dis-  
Solutions  
The thermostat’s screen is blank.  
The thermostat’s switch is on Standby.  
The measured temperature is below 0°C  
played. The icons of the current period and preset temperature are also dis-  
played.  
LO is displayed.  
(
32°F). Heating is activated.  
The measured temperature is above 50°C  
122°F).  
Temporary Bypass: If you modify the setpoint (by pressing the  
or button) when the thermostat is in automatic mode, the new set-  
point will be used until the end of the current period. When the next  
period starts, the temperature set for that period becomes the new set-  
point.  
,
,
HI is displayed.  
(
The thermostat was without power for  
more than 2 hours.  
The wrong time is displayed.  
The thermostat is located in a spot  
exposed to an air draft.  
The measured temperature is wrong.  
The heater is always On.  
Manual - The energy-saving schedule is not used. The temperature must  
Bad installation  
be set manually. To place the thermostat in this mode:  
The thermostat indicates that heating is On  
but the heater is not On.  
Bad installation  
n
o
Press Mode until  
Set the temperature using the  
Vacation - The thermostat is set to the Vacation temperature. Press  
is displayed.  
Check that the thermostat is in Automatic  
mode. Check also the energy-saving  
schedule and clock settings.  
The temperature does not change accord-  
ing to the energy-saving schedule  
,
,
or  
button.  
9
.
both  
mode.  
and  
buttons simultaneously to place the thermostat in Vacation  
Technical Specifications  
v
7
.
Power: 240 Vac, 50/60 Hz  
Energy-saving Schedule  
Load: 16.7 A maximum (resistive only)  
Power: 4000 watts (NI) @ 240 Vac  
Display range: 0°C to 60°C (32°F to 140°F)  
Display resolution: 0.1°C (0.1°F)  
Setpoint range: 5°C to 30°C (40°F to 86°F)  
Setpoint interval: 1°C (1°F)  
t
The schedule consists of 4 periods per day which represents a typical week  
day. You can program the thermostat to skip the periods that do not apply to  
your situation. For example, you can skip periods 2 and 3 for the weekend.  
Period  
Description  
Wake-up  
Associated preset temperature  
Storage: -20°C to 50°C (-4°F to 120°F)  
Approvals: CSA/UL  
Data backup: In the event of a power failure, most settings are saved. Only  
Away from home  
Return home  
Sleep  
the time must be re-adjusted if the power failure lasts more than 2 hours. The  
thermostat will return to the mode that was active prior to the power failure.  
10.  
Warranty  
;
Aube warrants this product, excluding battery, to be free from defects in the workmanship or materials,  
under normal use and service, for a period of three (3) years from the date of purchase by the  
consumer. If at any time during the warranty period the product is determined to be defective or  
malfunctions, Aube shall repair or replace it (at Aube's option).  
The Comfort ( ) temperature is used in periods 1 and 3 and the Economy  
) temperature is used in periods 2 and 4. For example, when the period  
changes from 1 to 2, the setpoint automatically changes from Comfort setting  
) to Economy setting ( ).  
(
If the product is defective,  
(i)  
return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased  
it, or  
(
(
ii) contact Aube. Aube will make the determination whether the product should be returned, or  
whether a replacement product can be sent to you.  
You can have a different program for each day of the week; i.e., each period  
can start at different time for each day of the week. The thermostat has been  
programmed with the following schedule.  
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown  
by Aube that the defect or malfunction was caused by damage which occurred while the product was in  
the possession of a consumer.  
Aube's sole responsibility shall be to repair or replace the product within the terms stated above. AUBE  
SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY  
INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM  
ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS  
PRODUCT. Some provinces and states do not allow the exclusion or limitation of incidental or  
consequential damages, so this limitation may not apply to you.  
Period Setting  
MO  
TU  
WE  
TH  
FR  
SA  
SU  
6
:00  
6:00  
AM  
6:00  
AM  
6:00  
AM  
6:00  
AM  
6:00  
AM  
6:00  
AM  
AM  
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT. THE  
DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF  
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE  
THREE-YEAR DURATION OF THIS WARRANTY. Some provinces and states do not allow limitations  
on how long an implied warranty lasts, so the above limitation may not apply to you.  
This warranty gives you specific legal rights, and you may have other rights which vary from province or  
state to another.  
8
:00  
8:00  
AM  
8:00  
AM  
8:00  
AM  
8:00  
AM  
-
-
-:--  
-:--  
--:--  
--:--  
AM  
6
:00  
6:00  
PM  
6:00  
PM  
6:00  
PM  
6:00  
PM  
PM  
11.  
1
0:00 10:00 10:00 10:00 10:00 10:00 10:00  
Customer Assistance  
PM PM PM PM PM PM PM  
If you have any questions about the product installation or operation, or concerning the  
warranty, contact us at:  
To modify the schedule:  
7
05 Montrichard  
n
o
Press Pgm to access the programming mode. Period 1 is selected.  
Saint-Jean-sur-Richelieu, Quebec  
J2X 5K8  
Canada  
Press Day to select the day to program (hold for 3 seconds to select the  
entire week).  
Tel.: (450) 358-4600  
Toll-free: 1-800-831-AUBE  
Fax: (450) 358-4650  
p
q
r
Press Hour and Min to set the start time of the selected period, or press  
Clear if you want to skip the period (--:-- is displayed).  
Email: aube.service@honeywell.com  
Press Pgm to select another period, or press Day to select another day.  
For more information on our products, go to  
Then repeat step 3.  
www.aubetech.com  
Press Mode to exit the programming mode.  
®
NOTE: If no button is pressed for 60 seconds, the thermostat will automati-  
cally exit the programming mode.  
As an ENERGY STAR partner, Aube Technologies has  
determined that this product meets the ENERGY STAR  
guidelines for energy efficiency.  
TH110  
400-110-000-A  
2/6/05  
2/2  

Honeywell H8908C Dehumidistat Thermostat User Manual

White Rodgers 1F87 361 Thermostat User Manual

Trane TCONT401AN21MA Thermostat User Manual

Honeywell Q7300L Thermostat User Manual

Honeywell Q674F,J Thermostat User Manual

Honeywell T7984 B Thermostat User Manual

Honeywell YCT87N1006 Thermostat User Manual

White Rodgers 1F86 241 Thermostat User Manual

White Rodgers 2B61 186 Thermostat User Manual

Emerson 1F83 277 Thermostat User Manual