Honeywell T8001 Thermostat User Manual

Home

href="
T8000, T8001,T8002, T8011, T8024  
Programmable Thermostats  
OWNER’S GUIDE  
6
9-1431-1  
Welcome to the world of comfort and energy  
savings with your new Honeywell program-  
mable thermostat.  
Features  
Program up to four time periods with  
temperature settings to complement  
your lifestyle.  
Your new programmable thermostat is designed  
to provide you with reliable, precise temperature  
control. When you follow the simple program-  
ming instructions in this manual, your thermostat  
automatically controls the temperature in your  
home, saving energy and allowing you to awake  
Set different schedules for weekdays and  
weekend.  
Programs permanently held in nonvolatile  
memory in event of power failure.  
Indefinite temperature hold.  
Preprogrammed for your convenience.  
Backlit display (select models).  
(or return home) to a comfortable level of heating  
or air conditioning.  
If you have questions, visit our web site at  
www.honeywell.com/yourhome, or call the  
customer information line at 1-800-468-1502.  
2
69-1431–1  
Contents  
Features .......................................................................................................................................... 2  
Key Locations and Descriptions ...................................................................................................... 4  
Planning Program Schedule ........................................................................................................... 5  
Program Schedule...................................................................................................................... 6  
Programming Thermostat ............................................................................................................... 7  
Setting Current Time and Day .................................................................................................... 8  
Setting Weekday Program .......................................................................................................... 9  
Setting Weekend Program ......................................................................................................... 10  
Setting Temporary Temperature Hold ......................................................................................... 13  
Setting Indefinite Temperature Hold ........................................................................................... 13  
Operating Thermostat ..................................................................................................................... 13  
Setting SYSTEM and FAN Switches .......................................................................................... 13  
Replace the Batteries (T8002 Only)........................................................................................ 14  
Backlighting (Select Models)................................................................................................... 14  
Minimum Off-Timing ........................................................................................................................ 15  
Troubleshooting .............................................................................................................................. 16  
Customer Assistance ...................................................................................................................... 19  
Warranty.......................................................................................................................................... 20  
3
69-1431–1  
href="
Key Locations and Descriptions  
HOLD KEY  
INCREASE KEY  
PROGRAM TIME AND TEMPERATURE.  
SET TEMPORARY TEMPERATURE  
HOLD.  
SELECT KEY  
• SET TEMPORARY TEMPERATURE HOLD.  
• CURRENT SETPOINT.  
• CHANGE DAY AND TIME.  
• PROGRAM SELECTIONS.  
INCREASE KEY  
PROGRAM TIME AND TEMPERATURE.  
SET TEMPORARY TEMPERATURE HOLD.  
SELECT KEY  
CURRENT SETPOINT.  
CHANGE DAY AND TIME.  
PROGRAM SELECTIONS.  
T8000,T8001  
T8011,T8024  
MODELS  
PM  
PM  
TUE  
TUE  
Hold  
Hold  
Select  
Select  
T8002 MODEL  
Au  
Ft oA NO n  
FAN  
Auto On  
Cool Off Heat  
SYSTEM  
Cool Off Heat  
SYSTEM  
FAN SWITCH  
FAN SWITCH  
BATTERY  
DOOR  
SYSTEM SWITCH  
DECREASE KEY  
• PROGRAM TIME AND TEMPERATURE.  
• SET TEMPORARY TEMPERATURE HOLD.  
SYSTEM SWITCH  
HOLD KEY  
SET TEMPORARY TEMPERATURE HOLD.  
M14673  
4
69-1431–1  
href="
Table 1. Preprogrammed Time  
and Temperature Settings.  
Planning Program Schedule  
The thermostat display shows day, time,  
program period, and temperature.  
Heat  
Setpoint  
Cool  
Setpoint  
Period  
Time  
Wake  
6:00 AM  
70°F  
21°C)  
78°F  
(26°C)  
The thermostat can be set for four time  
periods per day for weekdays and weekend.  
(
Leave 8:00 AM  
Return 6:00 PM  
Sleep 10:00PM  
62°F  
17°C)  
85°F  
(29°C)  
(
Before programming the thermostat, you can  
use the program schedule to plan your  
program.  
70°F  
(21°C)  
78°F  
(26°C)  
62°F  
17°C)  
82°F  
(28°C)  
Fill in the weekday and weekend times and  
temperatures you desire. If you decide not to  
program the thermostat, it uses the  
preprogrammed time and temperature settings  
in Table 1.  
(
5
69-1431–1  
Program Schedule  
Weekday  
Start Time  
Heating Temperature  
Cooling Temperature  
Wake  
Leave  
Return  
Sleep  
________  
________  
________  
________  
________  
________  
________  
________  
________  
________  
________  
________  
Weekend  
Start Time  
Heating Temperature  
Cooling Temperature  
Wake  
Leave  
Return  
Sleep  
________  
________  
________  
________  
________  
________  
________  
________  
________  
________  
________  
________  
Wake and Return start times should include extra lead time, based on outside temperature and  
equipment response time, to give your equipment a head start to heat or cool the house. The  
temperatures cannot be set any higher than 99°F (37°C) or any lower than 40°F (4°C).  
6
69-1431–1  
time, to give the equipment a head start to  
heat or cool the house before you get up.  
Programming Thermostat  
(
This will be a higher temperature during  
heating season, and a lower temperature  
during cooling season.)  
The thermostat is flexible and can be program-  
med for different schedules for weekdays and the  
weekend to meet your lifestyle needs.  
Leave is the time period you can set for an  
energy-saving temperature while you are  
away at work or school. (This will be a  
lower temperature during heating season,  
and a higher temperature during cooling  
season.)  
Use the personal Program Schedule for planning  
your time and temperature settings for various  
times of the day.  
Four time periods are available during weekdays  
and the weekend—Wake, Leave, Return, and  
Sleep.  
Return is the time the thermostat turns on the  
heating/cooling equipment after an energy  
saving period. When deciding what time to  
set for your Return period, include extra  
lead time, depending on the outside temp-  
erature and your equipment response time,  
to give the equipment a head start to heat  
or cool the house before you arrive home.  
Wake is the time the thermostat turns on the  
heating/cooling equipment after an energy  
saving period. When deciding what time to  
set for your Wake period, include extra  
lead time, depending on the outside temp-  
erature and your equipment response  
7
69-1431–1  
href="
Sleep is the time period you can set for an  
energy-saving temperature while you are  
sleeping. (For more comfortable sleep-  
ing, some people choose not to raise the  
cool temperature during the night.)  
While setting the current time, the word SET is  
displayed.  
2. To set day of week, press Select again.  
Press or ▲  
SET  
to set current  
day.  
IMPORTANT  
Always press the keys with your  
fingertip or similar blunt tool. Sharp  
instruments like pens and pencil  
points can damage the keyboard.  
M18534  
To use the preprogrammed time and tempera-  
ture (see Table 1), press Hold to exit the  
programming mode.  
Setting Current Time and Day  
1
. To set current time, press Select twice.  
Press or ▲  
to set current  
SET  
PM  
time.  
M12591A  
8
69-1431–1  
href="
4
. Leave  
Setting Weekday Program  
a. Press Select. Press  or  to set  
Slide the SYSTEM switch to the position, Heat  
or Cool, you want to program. A flame (heat-  
Leave  
time.  
SET  
ing) or a snowflake  
(cooling) appears in the  
right side of the display, when setting the  
program temperature.  
M18566  
3
. Wake  
b. Press Select. Press  or  to set  
a. Press Select. Press  or  to set  
Leave  
SET  
Wake  
time.  
SET  
temp-  
erature.  
M12627B  
M18570  
5. Return  
b. Press Select. Press  or  to set  
a. Press Select. Press  or  to set  
Wake  
SET  
Return  
time.  
SET  
temp-  
erature.  
M12625C  
M18567  
9
69-1431–1  
href="
b. Press Select. Press  or  to set  
Setting Weekend Program  
. Wake  
a. Press Select. Press  or  to set  
Return  
temp-  
SET  
7
erature.  
Wake  
time.  
SET  
M12629B  
6. Sleep  
a. Press Select. Press  or  to set  
M18569  
Sleep  
time.  
SET  
b. Press Select. Press  or  to set  
Wake  
SET  
temp-  
M18568  
erature.  
b. Press Select. Press  or  to set  
M12633C  
Sleep  
SET  
temp-  
erature.  
M12631C  
1
0
69-1431–1  
href="
8
. Leave  
b. Press Select. Press  or  to set  
a. Press Select. Press  or  to set  
Return  
SET  
Leave  
time.  
SET  
temp-  
erature.  
M12637B  
10. Sleep  
M18550  
a. Press Select. Press  or  to set  
b. Press Select. Press  or  to set  
Sleep  
time.  
SET  
Leave  
SET  
temp-  
erature.  
M18554  
M12635B  
9
. Return  
b. Press Select. Press  or  to set  
Sleep  
a. Press Select. Press  or  to set  
SET  
Return  
time.  
SET  
temp-  
erature.  
M12639C  
M18552  
1
1
69-1431–1  
href="
1
1. Press Select. End is displayed. Program-  
Setting Indefinite Temperature Hold  
The Hold key allows you to indefinitely hold a  
temperature. When Hold is active, the letters  
Hld are displayed continuously. Hold can be  
canceled by pressing the Hold key again.  
ming is complete. The thermostat reverts  
to displaying  
SET  
the current  
day time and  
temperature in  
five seconds.  
1. Press Hold  
M18556  
Setting Temporary Temperature Hold  
2
. Press  or  key to set indefinite  
temperature  
setting.  
1
. Press  or  key to set a temporary  
temperature  
TEMPORARY  
setting.  
PM  
WED  
M12641A  
M12640A  
NOTE: The temporary temperature setting  
remains in effect until the next program  
period. To cancel, press Hold twice.  
1
2
69-1431–1  
href="
Slide the SYSTEM switch in the lower right  
corner of the thermostat to select the desired  
system setting.  
Operating Thermostat  
Setting SYSTEM and FAN Switches  
Use the SYSTEM and FAN switches to control  
thermostat operation.  
FAN settings:  
Auto: Fan operates with equipment.  
On: Fan operates continuously.  
SYSTEM settings:  
Cool: The thermostat controls the cooling.  
Off: Both the heating and cooling are off.  
Heat: The thermostat controls the heating.  
Em. Ht. (heat pump models only): The  
thermostat cycles emergency heat relay  
Slide the FAN switch in the lower left corner of  
the thermostat to select the desired fan setting.  
Heat and Cool Indicators:  
Indicates a call for heat.  
Indicates a call for cool.  
(E) and cycles auxiliary heat (W2), as  
needed, to maintain setpoint. Terminal L is  
energized continuously (fault heat relay is  
on continuously). Compressor is de-  
energized.  
NOTE: In the programming mode, the  
and  
indicate system setting.  
1
3
69-1431–1  
The batteries are located on the right side of  
the thermostat. Open the battery door from the  
bottom, lifting out.  
Back Lighting (Select Models)  
Any key pressed lights the display for approxi-  
mately ten seconds.  
If you insert the batteries within approximately  
Replacing the Batteries  
30 seconds of removing the old batteries, the  
(
T8002 Models Only)  
thermosat retains the current time and day. If  
the display is blank when changing batteries,  
reset the time and day. Your program does not  
require resetting; it is stored permanently!  
The T8002 Thermostat requires three AA  
alkaline batteries to operate.  
As the batteries run low, your thermostat  
shows a "bAt Lo" message in the digital  
display. The message flashes for one to two  
months before the batteries run out completely.  
Replace the batteries as soon as possible after  
the message flashes.  
Important: Even if you do not see the "bAt Lo"  
message, replace the batteries once a year to  
prevent leakage and/or the heating/cooling  
system from shutting down due to lack of  
battey power.  
1
4
69-1431–1  
href="
Minimum Off-Timing  
The thermostat minimum off-timer assures that  
the compressor does not come on again for at  
least five minutes after it turns off. The minimum  
off-timer is triggered when the compressor turns  
off and when the SYSTEM switch position is  
changed. If the compressor turns off when the  
setpoint is changed, the minimum off-timer is  
triggered. Power interruption and power  
The minimum off-timer operates in cooling on  
the T8000 and T8001, T8002, T8024 (multi-  
stage model) and in first stage heating or  
cooling on the T8011 (heat pump model). A  
flashing flame or snowflake indicates the  
minimum off-time is in effect.  
restoration also trigger the minimum off-timer.  
1
5
69-1431–1  
href="
Troubleshooting  
Symptom  
Action  
Check if the thermostat is mounted and latched on  
the wallplate—mount and latch the thermostat on  
the wallplate.  
Check if the circuit breaker is tripped—reset the  
circuit breaker.  
Display does not come on.  
Check if the fuse is blown—replace the fuse.  
Check if the switch at the equipment is in the Off  
position—set to the On position.  
Check if the batteries are good and installed correctly  
(T8002 only).  
Temperature settings do not  
change (example: cannot set the  
heating higher or the cooling  
lower).  
Check that the temperature setpoints are: between  
40 to 99°F (4 to 37°C).  
continued  
1
6
69-1431–1  
href="
Troubleshooting (Continued).  
Symptom  
Action  
Heating does not come on.  
Check if the circuit breaker is tripped—reset the  
circuit breaker.  
Check if the fuse is blown—replace the fuse.  
Check if the switch at the equipment is in the Off  
position—set to On position.  
Wait five minutes for the system to respond.  
Set SYSTEM switch to Heat.  
If the temperature setting is higher than the current room  
temperature and the flame  
is displaying, the  
thermostat is operating correctly. Contact a heating  
contractor for assistance.  
continued  
1
7
69-1431–1  
href="
Troubleshooting (Continued).  
Symptom  
Action  
Cooling does not come on.  
Check if the circuit breaker is tripped—reset the  
circuit breaker.  
Check if the fuse is blown—replace the fuse.  
Check if the switch at the equipment is in the Off  
position—set to On position.  
Wait five minutes for the system to respond.  
Set SYSTEM switch to Cool.  
If the temperature setting is lower than the current room  
temperature and the snowflake  
is displaying, the  
thermostat is operating correctly. Contact an air  
conditioning contractor for assistance.  
continued  
1
8
69-1431–1  
href="
Troubleshooting (Continued).  
Symptom  
Action  
System on indicator  
Wait a couple minutes after seeing the flame or  
snowflake and then check the registers.  
or  
is lit, but no warm  
or cool air is coming from the  
registers.  
System on indicator  
Minimum off-timer is in effect. Wait five minutes until  
the minimum off-timer is complete.  
or  
is flashing.  
Customer Assistance  
If you have any questions concerning the operation of your thermostat, please visit us at www.honeywell.com or  
call the thermostat information helpline at 1-800-468-1502.  
1
9
69-1431–1  
Warranty  
Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials,  
under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If, at any  
time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at  
Honeywell’s option) within a reasonable period of time.  
If the product is defective,  
(
(
i) return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or  
ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of  
the malfunction, and mail it, postage prepaid, to the following address:  
Honeywell Return Goods  
Dock 4 MN10-3860  
1885 Douglas Drive North  
Golden Valley, MN 55422  
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by  
Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the  
possession of a consumer.  
2
0
69-1431–1  
Honeywell’s sole responsibility shall be to repair or replace the product within the terms stated above. HONEY-  
WELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL  
OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY  
WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not  
allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.  
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE  
DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND  
FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS  
WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation  
may not apply to you.  
This warranty gives you specific legal rights, and you may have other rights which vary from state to state.  
If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas  
Dr N, MN10-1451, Golden Valley, MN 55422. In Canada, write Retail Products ON15, Honeywell Limited/  
Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.  
2
1
69-1431–1  
href="
Automation and Control Solutions  
Honeywell  
Honeywell Limited-Honeywell Limitée  
985 Douglas Drive North  
Golden Valley, MN 55422  
1
35 Dynamic Drive  
Scarborough, Ontario  
M1V 4Z9  
Printed in U.S.A. on recycled  
paper containing at least 10%  
post-consumer paper fibers.  
69-1431–1 Rev. 5-02 G.H.  
Copyright © 2002 Honeywell All Rights Reserved ® U.S. Registered Trademark  
www.honeywell.com/yourhome  

Honeywell AC 220 7 Thermostat User Manual

White Rodgers 1F98EZ 1421 Thermostat User Manual

Lux Products PSPLV512d Thermostat User Manual

Honeywell TH2110D Thermostat User Manual

Hunter Fan T200 Thermostat User Manual8659

Honeywell CT87A Thermostat User Manual

Honeywell T8600D Thermostat User Manual

Lux Products TX250 Thermostat User Manual

Honeywell T694A Thermostat User Manual

Trane XL950 Thermostat User Manual