Aube TH132 AFAF Thermostat User Manual

Home

href="
TH1 32 Description  
Models Overview  
Configure the Switches  
Control Module  
The TH132 has two switches, located on the upper-left  
part on the rear of the control module, which are used to  
set the following options:  
TH1 32 A/ꢀ/Aꢀ  
! DAY/HOUR/MIN—Set the day and clock settings.  
TH132-A  
"
#
PGM—Program the schedule (programs).  
Owner!s Guide  
This model has been designed to control a room’s ambi-  
ent temperature.  
The TH132-A has one temperature sensor located in the  
control module.  
MODE—Select the operating mode.  
RETURN—To exit a function.  
Thank you for choosing the Aube TH132, a programma-  
ble thermostat that provides both energy savings and total  
comfort.  
Early Start  
When the Early Start function is enabled (disabled by  
default), the TH132 calculates the optimum system start  
time to obtain the desired temperature by the set time. To  
enable this function:  
$ To configure temperature setpoints:  
Comfort, Economy and Vacation.  
TH132-AF  
This model is designed to use a floor sensor to control the  
room temperature.  
The TH132-AF has two temperature sensors:  
%
&
'
Adjust the floor temperature limit (AF only).  
—Increase and decrease temperature.  
Position switch #1 down.  
Note: When this function is enabled, the  
system can be activated before the pro-  
gram’s start time.  
—Indicates the number of the current  
program when Automatic mode is enabled.  
The first one, installed in the control module, controls  
the ambient temperature.  
The second one, installed in the floor (and connected  
to the power base), limits the temperature of the floor  
(
Current operating mode (auto  
Auto mode, the program’s associated setpoint icon is  
also displayed ( ).  
manual ). In  
Temperature Display  
By default, the TH132 displays the temperature in °C. If  
you wish to change to °F:  
(
the default setting of this limit is 82°F).  
TH132-F  
)
*
Indicates the room OR floor temperature.  
This model is designed to control floor heating systems.  
The TH132-F has one temperature sensor installed in the  
floor (sensor is connected to the power base).  
Position switch #2 up.  
Heating indicators (see “Temperature Control”  
below).  
Note: When you switch from °C to °F or vice  
versa, the  
redefined.  
,
and  
setpoints must be  
WARNING: This control module has 20-second cycles  
and must be installed ONLY with a TRIAC relay.  
Install the Control Module  
ꢀirst Power ON  
Adjust the Temperature Setpoints  
Select the Operating Mode  
Align the bracket tabs on the control module with the  
holes located on top of the power base.  
This control module must be installed on a PB130-024T  
series power base.  
On the first installation, the screen displays:  
0:00, MO, and temperature (room/floor).  
Comfort  
and Economy Setpoints  
The TH132 offers three operating modes:  
These setpoints are associated with the schedule’s pro-  
grams (prog. 1 & 3 = Comfort, prog. 2 & 4 = Economy)  
and are preprogrammed as follows:  
Automatic —Executes the schedule.  
For Floor Heating Installations:  
One of the two following messages may be dis-  
played when a problem occurs:  
!
Press MODE to select  
program number is displayed.  
. The current  
A & AF models— 68°F, 64°F  
F model— 82°F, 68°F  
To modify a setpoint:  
You can temporarily bypass the current  
program by setting a specific temperature setpoint  
or by selecting one of the pre-defined setpoint  
LO: The floor temperature is below 32°F (0°C), or  
the temperature sensor is defective, or not  
connected.  
buttons (  
). The new setpoint will be maintained  
!
Set the temperature using and press and hold the  
or button until it is displayed on the screen.  
The heating indicator  
is displayed and  
until the beginning of the next program.  
the relay is closed (energized).  
HI: The floor temperature is above  
" Press MODE/RETURN to exit.  
Manual —Maintains a constant temperature.  
! Press MODE to select  
" Set temperature or select one of the pre-  
defined setpoint buttons ( ).  
1
40°F (60°C), or the temperature sensor is  
Vacation Setpoint  
.
defective.  
The vacation setpoint is associated to the Vacation oper-  
ating mode and is preprogrammed to 50°F. To modify this  
setpoint, repeat above steps.  
Set the Time and Day  
Vacation —Maintains the Vacation setpoint  
during a prolonged absence.  
Floor Temperature Setpoint (AF model only)  
The floor temperature limit is preprogrammed to 82°F to  
avoid damage to your floor.  
!
"
Set the time (HOUR - MIN).  
Set the day (DAY).  
Note: Keep the thermostat's air vents clean and free from  
Press  
.
obstructions.  
To modify, press the adjustment button (below ) using a  
Note: The screw cannot be removed completely.  
If you remove the module from its base for more than  
hours, the time and day will have to be reprogrammed.  
pointed object, set the desired temperature using  
press MODE/RETURN to exit.  
and  
2
4
00-132-012-A  
href="
Note: It is sometimes faster to program the same sched-  
ule for the entire week and then to modify the exception  
days.  
Programming Example  
$ Press PGM to select program 2.  
Program Your Schedule  
Set the time (8:30) using the HOUR and MIN buttons.  
% Repeat step 4 for remaining programs:  
program 3 (16:00) and program 4 (23:00).  
Programs  
MO  
:00 6:00 6:00 6:00 6:00 6:00 6:00  
8:30 8:30 8:30 8:30 8:30 --:-- --:--  
TU  
WE  
TH  
FR  
SA  
SU  
The schedule is used with the Automatic mode. The  
schedule controls the heating system to automatically  
switch between the Comfort and Economy temperature  
setpoints at the times you have programmed.  
The schedule consists of 4 programs per day defined as  
follows:  
6
#
$
Press PGM to select the program number (e.g. 1).  
Press HOUR and MIN to set the start time.  
&
When all programs are configured, press MODE/  
RETURN to exit.  
1
6:00 16:00 16:00 16:00 16:00 --:-- --:--  
3:00 23:00 23:00 23:00 23:00 23:00 23:00  
% Repeat steps 3 to 4 for remaining programs (e.g. 2, 3  
2
and 4).  
To erase programs 2 and 3 for Saturday and  
Sunday  
Time i  
& Press MODE/RETURN to exit.  
Programs  
Setpoint  
Comfort :  
!
Press PGM.  
Note: After 60 seconds of inactivity, the thermostat will  
automatically exit programming mode.  
• Monday to Friday, between 6:00 and 8:30 and  
between 16:00 and 23:00.  
• Saturday and Sunday, between 6:00 and 23:00.  
Wake-up  
" Press PGM to select program 2.  
# Press DAY to select SAturday (SA).  
$ Press CLEAR to erase the time (--:--).  
% Press DAY to select SUnday (SU).  
Leave home  
Back home  
To clear a program time:  
Economy :  
When you clear a program time entry, the TH132 will  
maintain the temperature setpoint of the last executed  
program until the beginning of the next program.  
• Monday to Friday, between 8:30 and 16:00 and  
between 23:00 and 6:00.  
Night  
&
'
Press CLEAR to erase the time (--:--).  
Saturday and Sunday, between 23:00 and 6:00.  
i.  
The programs’ start time can be different for each day of the week.  
! Repeat steps 1 to 3 above.  
Press PGM to select program 3.  
"
Press CLEAR to erase the time entry. The time por-  
tion of the LCD indicates --:-- when the program is  
inactive.  
To program this schedule  
( Repeat steps 3 to 6.  
) Press MODE/RETURN to exit.  
To enter the programs’ start time  
To shorten programming, you simply have to enter the  
start time for each program.  
! Press PGM.  
"
Press and hold DAY for 3 seconds to select all days  
of the week.  
#
Press MODE/RETURN to exit.  
!
"
Press PGM.  
#
Press PGM to select program 1.  
Set the time (6:00) using the HOUR and MIN buttons.  
Press DAY to select the day (hold for 3 seconds to  
select all days of the week).  
If you have any questions concerning the programming of  
the TH132 programmable thermostat, call our technical  
support team at:  
Temperature Control  
Technical Specifications  
Warranty  
The TH132 thermostat works differently than conventional  
electromechanical thermostats.  
It is equipped with a proportional integral adaptive (PIA)  
controller which determines heating cycles by analyzing  
the temperature behavior history within the room.  
The PIA controller reduces temperature swings providing  
accurate temperature control while increasing user com-  
fort.  
The controller determines the amount of power required  
by the heating system to maintain the setpoint tempera-  
ture.  
Model: TH132 A / AF / F  
AUBE TECHNOLOGIES INC. TWO (2) YEAR LIMITED WARRANTY  
This product is guaranteed against workmanship defects  
for a two-year period following the initial date of purchase.  
During this period, AUBE Technologies Inc. will repair or  
replace, at our option and without charge, any defective  
product which has been used under normal conditions.  
Display range: 32°F to 140°F (0°C to 60°C)  
Setting range (ambient): 40°F to 86°F (5°C to 30°C)  
Setting range (floor): 40°F to 104°F (5°C to 40°C)  
Pre-programmed temperature setpoints:  
Comfort: A/AF: 68°F (20°C) and F: 82°F (28°C)  
Economy: A/AF: 64°F (18°C) and F: 68°F (20°C)  
Vacation: A/F/AF: 50°F (10°C)  
705 Montrichard  
Saint-Jean-sur-Richelieu  
Quebec, Canada J2X 5K8  
10 rue Ampère  
95500 Gonesse  
France  
The warranty does not cover delivery costs and does not  
apply to products poorly installed or randomly damaged  
following installation.  
Tel.: (450) 358-4600  
33 (0) 1 34 07 99 00  
Toll Free: 1-800-831-AUBE  
Fax: (450) 358-4650  
This warranty cancels and replaces any other  
manufacturer's express or implied warranty as well as any  
other company commitment. AUBE Technologies Inc.  
cannot be held liable for related or random damages  
following the installation of this product.  
33 (0) 1 34 07 99 19  
Email: service@aubetech.com advaube@comintes.com  
Floor limit: AF: 82°F (28°C)  
When the heating system is activated, one of the following  
icons is displayed:  
Temperature resolution display scale: 0.1°  
Storage:-4°F to 120°F (-20°C to 50°C)  
Software: Class A  
For more information on our products, visit us at:  
www.aubetech.com  
The defective product as well as the purchase invoice  
must be returned to the place of purchase or mailed,  
prepaid and insured, to the nearest shipping address.  
Controller: Electronic  
1
to 20%  
21 to 40% 41 to 60% 61 to 80% 81 to 100%  
Temperature control: Proportional integral adaptive,  
2
0-second heating cycles  
Programming protection: Protected memory  
Clock protection: 2 hours  
®
As an ENERGY STAR partner, Aube Technologies has  
determined that this product meets the ENERGY STAR  
guidelines for energy efficiency.  
Size (H/W/D): 3.3 x 3.1 x 0.5 in (83 x 79 x 13 mm)  
2
0/04/2004 400-132-012-A  
href="
PB1 30-024T  
Installation Instructions  
2
4 V Low Voltage Power Base  
Introduction  
The PB130-024T power base is designed to power a TH13X Series  
control module. This low voltage power base can be used to drive a  
line voltage load using a relay or connect directly to equipment (such  
as a hot water system) using a 24 V signal.  
Although the PB130-024T is compatible with most relays, it has been  
optimized for use with an Aube relay. Aube offers triac relays (SSR)  
such as the RT850 and RT850T (with built-in 24 V transformer), and  
electromechanical relays such as the RC840 and RC840T (with built-  
in 24 V transformer).  
Installation Guidelines  
Cut power to the heating system at the main power panel to  
avoid electrical shock. Installation should be carried out by an  
electrician.  
For a new installation, choose a location about 5 ft. (1.5 m)  
above the floor.  
The thermostat should be installed facing the heating system  
and on an inside wall.  
Avoid locations where there are air drafts (top of staircase, air  
outlet), dead air spots (behind a door), direct sunlight or con-  
cealed chimneys or stove pipes.  
Included Parts  
n One (1) PB130-024T low voltage power base  
o Two (2) anchors  
p Two (2) mounting screws  
Installation Steps  
n Connect the base. See the typical wiring diagrams.  
a) Electric heating (figures 1, 2 and 3)  
Connect the base to the relay:  
Use a relay with a built-in 24 V transformer or  
Use a relay and an external 24 V transformer.  
Connect the relay to the load (see relay’s instructions).  
b) Hot water heating (figure 4)  
Connect the base to the 24 V valve of the  
water heating system.  
o For a floor heating installation, connect the  
floor sensor between the S and R terminals.  
Technical Specifications  
p Push the excess wire into the wall and secure the  
Maximum load: 0.5 A / 24 VAC  
base using the provided screws and wall anchors.  
Operating temperature: 32°F to 122°F (0°C to 50°C)  
Storage: -4°F to 122°F (-20°C to 50°C)  
Size (H • W • D): 2.94 x 2.94 x 0.53 in. (74.6 x 74.6 x 13.3 mm)  
Wire gauge: 14 to 22 AWG  
q Before mounting the control module onto the base, select the  
heating cycle, set the switches (if necessary) and mount the  
control module. Refer to the control module’s user guide for  
more information.  
r Once the control module is configured (switches) and installed,  
If you have any questions concerning the PB130-024T low  
voltage power base, call our technical support team at:  
return power to the heating system.  
7
05 Montrichard  
10 rue Ampère  
95500 Gonesse  
France  
AUBE TECHNOLOGIES INC. TWO (2) YEAR LIMITED WARRANTY  
Saint-Jean-sur-Richelieu  
Quebec, Canada J2X 5K8  
This product is guaranteed against workmanship defects for a two-year period following  
the initial date of purchase. During this period, AUBE Technologies Inc. will repair or  
replace, at our option and without charge, any defective product which has been used  
under normal conditions.  
Tel.: (450) 358-4600  
Toll Free: 1-800-831-AUBE  
Fax: (450) 358-4650  
33 (0) 1 34 07 99 00  
33 (0) 1 34 07 99 19  
The warranty does not cover delivery costs and does not apply to products poorly  
installed or randomly damaged following installation. This warranty cancels and replaces  
any other manufacturer's express or implied warranty as well as any other company  
commitment.  
Email: service@aubetech.com advaube@comintes.com  
AUBE Technologies Inc. cannot be held liable for related or random damages following  
the installation of this product. The defective product as well as the purchase invoice  
must be returned to the place of purchase or mailed, prepaid and insured, to the  
following address.  
For more information on our products, visit us at:  
www.aubetech.com  
1
4/11/2003 400-130-002-B  

Honeywell T8621A Thermostat User Manual

Honeywell T8185 Thermostat User Manual

Lux Products T20 1141 Thermostat User Manual

Hunter Fan 40020 Thermostat User Manual

Honeywell 69 1490 Thermostat User Manual

Honeywell T8775C Thermostat User Manual

Aube TH150 Series Thermostat User Manual

Honeywell T4039C Thermostat User Manual

Honeywell V8944C Thermostat User Manual

Aprilaire 8348 Thermostat User Manual