Bryant TSTAT Thermostat User Manual

Home

href="
THERMOSTATS  
THERMIDISTAT CONTROL  
MODEL  
TM  
TSTAT  
The Bryant electronic thermostat product line consists of pro-  
grammable and non-programmable air conditioner, heat pump,  
ELECTRO-MECHANICAL THERMOSTATS  
and 2-speed models; a programmable dual fuel model, and a  
HEAT OFF COOL  
80  
TM  
programmable Thermidistat  
Control. These units feature  
90  
80  
70  
60  
80  
70  
60  
50  
non-mercury based electronic controls built into a subtle, slim  
plastic enclosure. They require no battery back-up and are not  
power stealing. Bryant also offers conventional electro-  
mechanical thermostats in both air conditioner and heat pump  
models.  
7
0
0
6
50  
AUTO FAN ON  
EM. HEAT HEAT OFF COOL  
FAN AUTO ON  
EM. HEAT AUX. HEAT  
*
Air Conditioner Model  
* Heat Pump Model  
(HH07AT214)  
FEATURES/BENEFITS  
(HH07AT212)  
ELECTRO-MECHANICAL THERMOSTATS  
COMPLETE OFFERING—Non-programmable air conditioner  
and heat pump models available.  
EASY TO USE—Manual switches provide easy changes to heat-  
ing/cooling mode operation, fan operation, and desired  
temperature setting.  
NON-PROGRAMMABLE THERMOSTAT  
MANUAL CHANGEOVER—Allows manual switches in system  
operation when both heating and cooling are needed on the  
same day.  
®
NON-PROGRAMMABLE THERMOSTATS  
CLEAN DESIGN—Features soft, responsive buttons and an  
easy-to-read backlit Liquid Crystal Display (LCD).  
ACCURATE, RELIABLE TEMPERATURE CONTROL—LCD  
shows current room temperature at all times, and desired temper-  
ature prompts upon demand.  
*
Standard Model (AC, HP, 2S)  
AUTO CHANGEOVER—Switches system operation automati-  
cally when both heating and cooling are needed on the same day.  
OUTDOOR TEMPERATURE DISPLAY—Allows a check of the  
temperature outside before leaving home. (Optional on all models  
except non-programmable air conditioner.)  
CLEAN FILTER INDICATOR—Tells when it is time to clean the  
PROGRAMMABLE THERMOSTAT  
AND THERMIDISTAT CONTROL  
system’s filter.  
TM  
PERFECT COMPLEMENT—Completes your Bryant total com-  
fort system needs.  
LIMITED WARRANTY—Standard 1-year warranty available on  
®
all parts.  
PROGRAMMABLE THERMOSTATS  
Bryant programmable thermostats possess the same features as  
non-programmable thermostats plus:  
COMFORT AND ENERGY SAVINGS—Seven day program-  
ming, with 4 temperature changes provided per day, means  
comfort when the family is at home and savings through reduced  
energy usage when the family is away or asleep.  
*
*
*
Standard Model (AC, HP, 2S)  
Dual Fuel Model (DF)  
Thermidistat Control Model (RH)  
EASY TO USE—Simple instructions are located inside the ther-  
mostat’s door.  
TM  
Form No. PDS TSTAT.0.1  
href="
THERMIDISTATTM CONTROL  
DUPLICATE PROGRAMMING—Copy  
the comfort schedule from one day to the  
next using the copy previous day  
function.  
fies during cooling.  
AUTOMATIC HUMIDITY  
MENT—When used with the outdoor  
temperature sensor, the Thermidistat  
Control automatically adjusts the humid-  
ity setting reducing excess condensation  
on the windows.  
Bryant’s Thermidistat Control can be used  
to control any equipment application ex-  
cept zoning. It possesses all the features  
and benefits of Bryant’s non-programma-  
ble and programmable thermostats plus:  
ADJUST-  
OVERRIDE CAPABILITY—Hold func-  
tion allows the regular schedule to be  
bypassed with a temporary setting.  
ENHANCED COMFORT—Allows the ho-  
meowner to accurately maintain the  
desired temperature and humidity set-  
tings in the home. By combining the  
functions of a programmable thermostat  
and a humidistat, the Thermidistat Control  
provides temperature control, humidity  
control, and dehumidification.  
BATTERY-FREE—Non-volatile RAM chip  
requires no battery backup. Program is re-  
tained in memory so reprogramming is not  
required after power loss.  
VACATION MODE—With a single touch  
of a button, vacation mode adjusts all  
comfort levels for optimum efficiency  
while the home is unoccupied—or re-  
stores the settings to normal upon return.  
TIMEGUARD—Equipment protection.  
DUAL FUEL MODEL—The dual fuel  
thermostat can be used to control a gas  
furnace and a heat pump. This thermostat  
eliminates the need for an interface con-  
trol kit.  
SMART RECOVERY—Provides consis-  
tent heating and cooling right on time as it  
gradually adjusts indoor temperatures be-  
fore a scheduled change.  
HUMIDITY CONTROL—The Thermidi-  
stat Control accurately controls humidity.  
It humidifies during heating and dehumidi-  
MODEL NUMBER NOMENCLATURE  
ELECTRONIC THERMOSTATS  
T STAT  
BH  
N
AC  
01  
–A  
SERIES  
QUANTITY  
AC – AIR CONDITIONING�  
HP – HEAT PUMP�  
2S – TWO SPEED/TWO STAGE�  
DF – DUAL FUEL�  
RH – RELATIVE HUMIDITY (THERMIDISTAT CONTROL)  
P – PROGRAMMABLE�  
N – NON-PROGRAMMABLE  
BH – BRYANT BRAND  
A96562  
THERMOSTAT  
ELECTRO-MECHANICAL THERMOSTATS  
HH07AT  
XXX  
THERMOSTAT  
As an ENERGY STARSM Partner,  
Bryant Heating & Cooling Systems  
has determined that the  
programmable thermostats and  
Thermidistat Control meet the  
ENERGY STAR guidelines for  
energy efficiency.  
2
12 = NON-PROGRAMMABLE, AC�  
214 = NON-PROGRAMMABLE, HP  
A97379  
2—  
href="
DIMENSIONS  
1 3  
8″  
®
3 1  
2″  
5 1316″  
Non-Programmable Thermostat  
1 3  
8″  
4 3  
8″  
7 3  
8″  
Programmable Thermostat and Thermidistat Control  
1 3  
8″  
HEAT OFF COOL  
9
0
0
8
2 7  
70  
8″  
60  
AUTO FAN ON  
4 3  
4″  
Electro - Mechanical Air Conditioner Thermostat  
2 1  
16″  
8
0
0
80  
7
7
0
0
6
3 1  
50  
60  
4″  
50  
EM. HEAT HEAT OFF COOL  
FAN AUTO ON  
EM. HEAT AUX. HEAT  
4 1116″  
Electro - Mechanical Heat Pump Thermostat  
A97289  
3—  
PRODUCT DATA INFORMATION  
PHYSICAL CHARACTERISTICS  
Dimensions: See drawing  
Appearance: Plastic, eggshell color, textured  
ELECTRICAL CHARACTERISTICS  
Input Volts/Amps: 24vac, 5 VA  
ENVIRONMENTAL REQUIREMENTS:  
Operating Temperature/Relative Humidity: 32°F (0°C) to 104°F (40°C)/95% rh non-condensing  
Storage Temperature/Relative Humidity: –40°F (–40°C) to 134°F (56°C)/95% rh non-condensing  
PROGRAM SPECIFICATIONS:  
Non-Programmable Models:  
Temperature setpoint range: 40°F (4°C) to 90°F (32°C)  
Separate heat and cool setpoints  
Auto changeover  
Clean filter reminder: installer adjustable  
Permanent memory  
Programmable Models:  
Temperature setpoint range: 40°F (4°C) to 90°F (32°C)  
Separate heat and cool setpoints  
Auto changeover  
Clean filter reminder: installer adjustable  
Permanent memory  
Programming days: 7 day  
Programming periods: 4—Wake, Day, Eve, Sleep  
Hold function  
Copy previous day function  
Humidity display and control (Thermidistat Control only)  
WIRING REQUIREMENTS:  
Power: 24vac nominal, 18- to 30-vac, 50/50 Hz  
Wiring: Standard thermostat wire 18 to 24 gage.  
4—  
href="
DESCRIPTION  
PROGRAMMABLE ELECTRONIC THERMOSTATS  
PART NO.  
DESCRIPTION  
TSTATBHPAC01-A  
TSTATBHPHP01-A  
TSTATBHP2S01-A  
Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, 1-Stage Heat/1-Stage Cool  
Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat/1-Stage Cool  
Thermostat, Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat/2-Stage Cool  
in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode  
TSTATBHPDF01-A*  
TSTATBHPRH01-A*  
Dual Fuel Thermostat, Must Be Used with Outdoor Air Temperature Sensor (TSTATXXSEN01)  
Thermidistat Control — Programmable Thermostat with Humidity Control  
NON-PROGRAMMABLE ELECTRONIC THERMOSTATS  
PART NO.  
DESCRIPTION  
TSTATBHNAC01-A  
TSTATBHNHP01-A  
TSTATBHN2S01-A  
Thermostat, Auto Changeover, Non-Programmable, °F/°C, 1-Stage Heat/1-Stage Cool  
Thermostat, Auto Changeover, Non-Programmable, °F/°C, 2-Stage Heat/1-Stage Cool  
Thermostat, Auto Changeover, Non-Programmable, °F/°C, 2-Stage Heat/2-Stage Cool  
in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode  
MECHANICAL MODELS  
PART NO.  
HH07AT212  
HH07AT214*  
DESCRIPTION  
Thermostat, Air Conditioner, Non-Programmable, 1-Stage Heat/1-Stage Cool, Manual Changeover, °F  
Thermostat, Heat Pump, Non-Programmable, 2-Stage Heat/1-Stage Cool, Manual Changeover, °F  
*
Do not use in zoning heat pump applications.  
THERMOSTAT ACCESSORIES  
PART NO.  
DESCRIPTION  
TSTATXXSEN01*  
TSTATXXNBP01†  
TSTATXXPBP01†  
TSTATXXCNV10‡  
Outdoor Air Temperature Sensor  
Backplate for Non-Programmable Thermostat  
Backplate for Programmable Thermostat and Thermidistat Control  
Thermostat Conversion Kit (4 to 5 wire) — 10 pack  
*
Outdoor air temperature sensor is an accessory for all Bryant electronic thermostats, except the non-programmable air conditioner version. It allows the  
temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the Thermidistat  
Control to automatically adjust humidity setting.  
The outdoor air temperature sensor must be used with the dual fuel thermostat. Do not use with electro-mechanical models.  
Thermostat backplate can be used for programmable and non-programmable electronic thermostats only. This plate is designed to cover surrounding wall  
area located behind thermostat.  
Thermostat conversion kit is a 24-vac accessory that can turn a 4-wire thermostat application into a 5-wire application.This kit can also be used to replace  
a broken thermostat wire, or add an extra wire when needed.  
5—  
href="
THERMOSTAT AND THERMIDISTAT CONTROL APPLICATION  
NON-PROGRAMMABLE ELECTRONIC THERMOSTAT USAGE  
OUTDOOR UNIT  
Air Conditioner  
Heat Pump  
INDOOR UNIT  
1 Speed  
2 Speed  
Model 2S  
Model 2S  
Model 2S  
Model 2S  
1 Speed  
2 Speed  
Model 2S‡  
Model 2S‡  
Model 2S  
Model 2S  
1-Stage Furnace  
Model AC or HP*  
Model AC or HP*  
Model AC or HP*  
Model AC or HP*  
2-Stage Furnace  
Typical Fan Coil  
FK4C Fan Coil  
Model HP  
Model HP  
*
Model HP thermostat must be field converted to air conditioner operation.  
Must use Programmable Dual Fuel Thermostat or Thermidistat Control in this application.  
Dual Fuel operation controlled by heat pump when using Model 2S Thermostat.  
Non-Programmable Models  
The TSTATBHNAC01-A Electronic Thermostat provides single-stage, non-programmable heat/cool temperature control for 24-vac  
heating-cooling systems with auto changeover. Temperature display can be selected to read °F or °C.  
The TSTATBHNHP01-A Electronic Thermostat provides versatile 2-stage heating and single-stage cooling, non-programmable tem-  
perature control for 24-vac heating-cooling systems with auto changeover. Temperature display can be selected to read °F or °C.  
Thermostat comes factory set to operate as a heat pump model with second-stage controlling auxiliary electric heat. This model can  
easily be converted from heat pump operation to air conditioning operation requiring 2 stages of gas or electric heat.  
The TSTATBHN2S01-A Electronic Thermostat provides versatile multiple stage, non-programmable heat/cool temperature control for  
24-vac heating-cooling systems with auto changeover. Temperature display can be selected to read °F or °C. Thermostat is  
designed for 2-speed compressor bearing units. Thermostat comes factory set to operate as a heat pump model with 2-stage cooling  
and 3 stages of heat, third-stage controlling auxiliary electric heat. This model can easily be converted from heat pump operation to  
air conditioning operation requiring 2 stages of cooling and 2 stages of heating.  
PROGRAMMABLE ELECTRONIC THERMOSTAT USAGE  
OUTDOOR UNIT  
Air Conditioner  
Heat Pump  
INDOOR UNIT  
1 Speed  
2 Speed  
Model 2S  
Model 2S  
Model 2S  
Model 2S  
1 Speed  
Model DF  
2 Speed  
Model DF or 2S‡  
Model DF or 2S‡  
Model 2S  
1-Stage Furnace  
Model AC or HP*  
Model AC or HP*  
Model AC or HP*  
Model AC or HP*  
2-Stage Furnace  
Model DF  
Typical Fan Coil  
FK4C Fan Coil  
Model HP  
Model HP or 2S†  
Model 2S  
*
Model HP thermostat must be field converted to AC operation.  
For use with special 3-stage electric heat setup.  
Dual Fuel operation controlled by heat pump when using Model 2S thermostat.  
Programmable Models  
The TSTATBHPAC01-A Electronic Thermostat provides single-stage, 7-day programmable heat/cool temperature control for 24-vac  
heating-cooling systems with auto changeover. Temperature display can be selected to read °F or °C.  
The TSTATBHPHP01-A Electronic Thermostat provides versatile 2-stage heating and single-stage cooling, 7-day programmable  
temperature control for 24-vac heating-cooling systems with auto changeover. Temperature display can be selected to read °F or °C.  
Thermostat comes factory set to operate as a heat pump model with second-stage controlling auxiliary electric heat. This model can  
easily be converted from heat pump operation to air conditioning operation requiring 2 stages of gas or electric heat.  
The TSTATBHP2S01-A Electronic Thermostat provides versatile multiple stage, 7-day programmable heat/cool temperature control  
for 24-vac heating-cooling systems with auto changeover. Temperature display can be selected to read °F or °C. Thermostat is  
designed primarily for 2-speed compressor bearing units. Thermostat comes factory set to operate as a heat pump model with 2-  
stage cooling and 3-stages of heat, third-stage controlling auxiliary electric heat.This model can also perform smart-staging with FK4  
fan coils (special heaters and setup required) using a single-speed heat pump with 3-stages auxiliary electric heat. In addition, this  
model can easily be converted from heat pump operation to air conditioning operation requiring 2 stages of cooling and 2 stages of  
heating (e.g. gas or electric heat).  
6—  
href="
Programmable Dual Fuel Model  
The TSTATBHPDF01-A Electronic Thermostat provides single-stage or multiple-stage dual fuel operation, 7-day programmable heat/  
cool temperature control for 24-vac systems with auto changeover. Temperature display can be selected to read °F or °C. The Dual  
Fuel Thermostat is designed with an adjustable balance point for heat pumps when using a gas furnace for backup or auxiliary heat.  
Thermostat comes factory set to operate single-speed equipment, but is easily configured to match multiple stage equipment combi-  
nations. This model requires use of the Outdoor Air Temperature Sensor accessory. Using the dual fuel thermostat eliminates the  
need for an interface control.  
THERMIDISTAT CONTROL USAGE  
OUTDOOR UNIT  
Air Conditioner  
Heat Pump  
INDOOR UNIT  
1 Speed  
2 Speed  
1 Speed  
2 Speed  
1-Stage Furnace  
2
-Stage Furnace  
Model RH*  
Typical Fan Coil  
FK4C Fan Coil  
*
The Thermidistat Control may be used in all applications but must be field configured for specific application.  
Thermidistat Control  
The TSTATBHPRH01-A Electronic Thermidistat Control provides single-stage or multiple-stage equipment operation, 7-day program-  
mable heat/cool temperature control for 24-vac systems with auto changeover. It controls both humidification and dehumidification  
and can be used to control heat pumps, air conditioners, or dual fuel applications. Temperature display can be selected to read °F or  
°C. The Thermidistat Control is designed primarily as an extension of the programmable thermostat line to provide humidify and  
dehumidify outputs in controlling humidity. Humidify outputs connect directly to 24-v humidifiers. Dehumidify outputs connect directly  
to variable-speed furnaces or fan coils that have dehumidification capabilities. This model requires use of the Outdoor Air Tempera-  
ture Sensor accessory, which is included with the Thermidistat Control.  
7—  
href="
OPERATIONAL INFORMATION FOR ELECTRONIC MODELS  
FIVE-MINUTE COMPRESSOR TIMEGUARD  
This timer prevents the compressor from starting unless it has been off for at least 5 minutes. It can be defeated for 1 cycle by simulta-  
neously pressing the FAN mode button and INCREASE TEMPERATURE (UP) button.  
FIFTEEN-MINUTE CYCLE TIMER  
This timer prevents the start of a heating or cooling cycle until at least 15 minutes after the last start of the same cycle. Its function is to  
assure that equipment is not cycled more than 4 times per hr. This timer is defeated for 1 cycle when the desired temperature is manu-  
ally changed. It can also be defeated for 1 cycle by simultaneously pressing the FAN mode button and INCREASE TEMPERATURE  
button.  
FIFTEEN-MINUTE STAGING TIMER  
In multistage heating or cooling, this timer prevents any higher stage from turning on until preceding stage has been on for 15 minutes.  
This timer is defeated if temperature error is greater than 5°F (usually due to a large change in desired temperature).  
MINIMUM ON TIME  
In normal operation, when a stage turns on, it will not turn off for a minimum of 2 minutes (3 minutes on Thermidistat Control).  
HEAT/COOL SETPOINTS (DESIRED TEMPERATURE)  
A minimum difference of 3° is enforced between heating and cooling desired temperatures. This is done by allowing 1 setting to “push”  
the other, to maintain this difference. (Thermidistat Control 2° and adjustable.)  
EQUIPMENT ON INDICATORS (THERMIDISTAT CONTROL)  
When cooling equipment is ON, a COOL icon preceded by a small triangle is displayed below the cool setpoint. While cooling equip-  
ment turn on is delayed by a staging or cycle timer, the triangle will be flashing. The same is true for the HEAT icon and its preceding  
triangle located under the heat setpoint. These 2 triangles are also used to indicate the state of the humidify and dehumidify outputs.  
See next section.  
HUMIDIFY/DEHUMIDIFY OUTPUT ON INDICATORS (THERMIDISTAT CONTROL)  
Within humidity select screen (selected by Humidity button and indicated by “hu” or “dhu” on clock display), the triangle under humidity  
setpoint will be on while humidify output is on.The triangle under dehumidify setpoint will be on while dehumidify output is active (turned  
off, because this output is reverse logic).  
AUTO CHANGEOVER  
When auto changeover mode is selected, a change from heat to cool (or vice versa) will not occur until an opposite mode demand has  
existed for 20 minutes. If setpoint is changed, the 20 minute requirement is deleted.  
EMERGENCY HEAT MODE  
When thermostat is controlling as a heat pump and emergency heat is selected, all Y signals are locked out, and W becomes energized  
upon a call for heat.  
SMART RECOVERY  
With Smart Recovery selected, transition out of setback begins a fixed time period before selected recovery time and gradually adjusts  
room temperature so that the desired temperature will be achieved at selected recovery time.  
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE  
UNIT MUST BE INSTALLED IN ACCORDANCE  
WITH INSTALLATION INSTRUCTIONS  
Cancels: New  
©
1997 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231  
—8—  
PRINTED IN U.S.A.  
Catalog No. 12TS-TA0  
8-97  

Honeywell T8775C Thermostat User Manual

Trane TCONT900AC43UA Thermostat User Manual

Aube 50 1133 Thermostat User Manual

Honeywell PCR 100 Thermostat User Manual

Honeywell AQ1000TN2 Thermostat User Manual

Honeywell CT51A Thermostat User Manual

Honeywell CT87K Thermostat User Manual

Honeywell RTH2410 Thermostat User Manual

White Rodgers 1F83 0422 Thermostat Thermostat User Manual

Bryant OM 17 101 Thermostat User Manual